<?xml version="1.0" encoding="ISO-8859-15" ?>
<rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom">
<channel>
                <title>SWD.de/+ Manufacturer +/Kollewin Technology Co., Ltd./KOL-Siemens S7-200 Adapter, PPI Cable for SIMATIC S7-200 PLC products</title>
        <link>https://oxid4.swd.de/oxid/Manufacturer/Kollewin-Technology-Co-Ltd/KOL-Siemens-S7-200-Adapter-PPI-Cable-for-SIMATIC-S7-200-PLC/</link>
        <description>KOL-Siemens S7-200 Adapter, PPI Cable for SIMATIC S7-200 PLC category's articles</description>
        <language>en</language>
        <copyright>SWD.de</copyright>
        <lastBuildDate>Sat, 30 Apr 2022 11:18:12 +0200</lastBuildDate>
        <generator>SWD.de</generator>
                    <managingEditor>order@swd.de (Uwe Wannags)</managingEditor>
                        <image>
            <url>https://oxid4.swd.de/oxid/out/swd/img/logo.png</url>
            <title>SWD.de/+ Manufacturer +/Kollewin Technology Co., Ltd./KOL-Siemens S7-200 Adapter, PPI Cable for SIMATIC S7-200 PLC products</title>
            <link>https://oxid4.swd.de/oxid/Manufacturer/Kollewin-Technology-Co-Ltd/KOL-Siemens-S7-200-Adapter-PPI-Cable-for-SIMATIC-S7-200-PLC/</link>
        </image>
        
        <atom:link href="https://oxid4.swd.de/oxid/rss/Category/KOL-Siemens-S7-200-Adapter-PPI-Cable-for-SIMATIC-S7-200-PLC/" rel="self" type="application/rss+xml" />
                    <item>
                <title>KOL-PC/PPI 33,00 ¤</title>
                <link>https://oxid4.swd.de/oxid/Products-oxid/Hardware/Fieldbus-Hardware/KOL-PC-PPI.html</link>
                <pubDate>Thu, 06 Mar 2014 15:42:13 +0100</pubDate>
                <description>&lt;img src=&#039;https://oxid4.swd.de/oxid/out/pictures/generated/product/1/150_150_75/KOl-PC-PPI-1.jpg&#039; border=0 align=&#039;left&#039; hspace=5&gt;&lt;p&gt;&lt;span style=&quot;color:#B22222;&quot;&gt;&lt;span style=&quot;font-size:16px;&quot;&gt;&lt;strong&gt;PC/PPI:programming cable for S7-200PLC&lt;/strong&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;img alt=&quot;&quot; src=&quot;/upload/images/Kollewin/Replace-S7-200-Analog/PC-PPI-programming%20cable%20for%20S7-200PLC.jpg&quot; style=&quot;width: 200px; height: 197px;&quot; /&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&lt;span style=&quot;line-height: 13px; font-family: tahoma, arial, helvetica, sans-serif;&quot;&gt;RS232/PPI interface,programming cable for Siemens S7-200PLC ,3 meters,can replace 6ES7 901-3CB30-0XA0,not support long distance communication and multi-master&lt;/span&gt;&lt;br style=&quot;color: rgb(50, 67, 74); font-size: 13px; line-height: 13px; font-family: tahoma, arial, helvetica, sans-serif;&quot; /&gt;
&lt;span style=&quot;line-height: 13px; font-family: tahoma, arial, helvetica, sans-serif;&quot;&gt;station communication.&lt;/span&gt;&lt;br style=&quot;color: rgb(50, 67, 74); font-size: 13px; line-height: 13px; font-family: tahoma, arial, helvetica, sans-serif;&quot; /&gt;
&lt;br style=&quot;color: rgb(50, 67, 74); font-size: 13px; line-height: 13px; font-family: tahoma, arial, helvetica, sans-serif;&quot; /&gt;
&lt;span style=&quot;line-height: 13px; font-family: tahoma, arial, helvetica, sans-serif;&quot;&gt;Not isolated,so it doesn&amp;#39;t support hot plug,if need isolated cable,pls choose PC/PPI+,you can click the following website for PC/PPI+:&amp;nbsp;&lt;/span&gt;&lt;a href=&quot;http://swd.de/oxid/Manufacturer/Kollewin-Technology-Co-Ltd/Siemens-S7-200-Adapter-PPI-Cable-for-SIMATIC-S7-200-PLC/KOL-PC-PPI-oxid.html&quot;&gt;http://swd.de/oxid/Manufacturer/Kollewin-Technology-Co-Ltd/Siemens-S7-200-Adapter-PPI-Cable-for-SIMATIC-S7-200-PLC/KOL-PC-PPI-oxid.html&lt;/a&gt;&lt;br /&gt;
&lt;br style=&quot;color: rgb(50, 67, 74); font-size: 13px; line-height: 13px; font-family: tahoma, arial, helvetica, sans-serif;&quot; /&gt;
&lt;span style=&quot;line-height: 13px; font-family: tahoma, arial, helvetica, sans-serif;&quot;&gt;The quality is guaranteed.It&amp;#39;s tested before shippment.Not made by&amp;nbsp;Siemens,OEM product as the replacement.&lt;/span&gt;&lt;/span&gt;&lt;br style=&quot;color: rgb(50, 67, 74); font-size: 13px; line-height: 13px; font-family: tahoma, arial, helvetica, sans-serif;&quot; /&gt;
&amp;nbsp;&lt;/p&gt;</description>
                <guid isPermaLink="true">https://oxid4.swd.de/oxid/Products-oxid/Hardware/Fieldbus-Hardware/KOL-PC-PPI.html</guid>
                            </item>
                    <item>
                <title>KOL-PC/PPI+ 76,00 ¤</title>
                <link>https://oxid4.swd.de/oxid/Products-oxid/Hardware/Fieldbus-Hardware/KOL-PC-PPI-oxid.html</link>
                <pubDate>Thu, 06 Mar 2014 15:43:04 +0100</pubDate>
                <description>&lt;img src=&#039;https://oxid4.swd.de/oxid/out/pictures/generated/product/1/150_150_75/KOL-PC-PPI-plus-1.jpg&#039; border=0 align=&#039;left&#039; hspace=5&gt;&lt;h1 class=&quot;productGeneral&quot; id=&quot;productName&quot; style=&quot;margin: 0.3em; font-size: 13px; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;strong style=&quot;color:#B22222;font-size:16px;&quot;&gt;PC/PPI+:optoelectronic isolated PC/PPI cable&lt;/strong&gt;&lt;/h1&gt;

&lt;p&gt;&amp;nbsp;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;optoelectronic isolated PC/PPI cable,support 10 bit and 11 bit modem communication,with communication indicator,automatically adjust the baud rate from 0 to 115.2Kbps,the largest communication distance of up to 2 kilometers.Not support&amp;nbsp; multi-master station communication.&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;nbsp;&amp;nbsp; The PC/PPI+ programming cable is the transformation electric cable from RS232 to the PPI connection (RS485), and it is suitable for Simens S7-200 series PLC, the correspondence and the monitoring. It also supports the PPI agreement and the free mouth communication protocol, and can use MODEM (modem) through the telephone line to make a long-distance correspondence. Since the cable is isolated with the electro-optical and built-in anti-static, surge and other transient over-voltage protection circuit, it solves the problem that the communication I always burned easily well. And it is especially suitable for the long-term monitoring communications which are under the industrial site with a poor environment.&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;Main technical parameters&amp;#65306;&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9733;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; Isolation voltage: 1000VDC&amp;#65288;The maximum to 3000 VDC, orders required statement&amp;#65289;&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9733;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; According to a transient voltage suppression. The RS485 port can withstand the power of up to 500 W transient over-voltage and lightning impact&amp;#65292;the RS232 port and power circuit are equipped with surge protection to protect the circuit. The whole product can be arbitrarily charged plug.&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9733;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; Baud rate&amp;#65306;0&amp;#65374;115.2kbps Adaptive&amp;#65288;products available for sale since January 2008&amp;nbsp;&amp;#65289;&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9733;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; The longest communication distance&amp;#65306;2 km&amp;#65288;Baud rate:9600bps per hour&amp;#65289;&amp;#65292;1km&amp;#65288;Baud rate:115.2Kbps per hour&amp;#65289;&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9733;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; With a power indicator light and the data received and sent indicator light&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9733;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; Temperature:-40&amp;#65374;85&amp;#8451;&amp;#65288;products available for sale since January 2008&amp;#65289;&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9733;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; Dimension&amp;#65306;103&amp;times;50&amp;times;26&amp;#65292;The total length of cable is 5m.&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;The product structure&amp;#65306;&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;img alt=&quot;&quot; src=&quot;/upload/images/Kollewin/Siemens%20Accessories/PC-PPI%2B-2.jpg&quot; style=&quot;width: 490px; height: 286px;&quot; /&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;The use of products&amp;#65306;&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;1&amp;#12289; PLC and computer connections for the PPI or free Communication, programming&amp;#65306;&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; Insert the PC / PPI + cable&amp;rsquo;s RS485 plug into the programming mouth of S7-200PLC and the RS232 plug into the computer&amp;rsquo;s RS232 port. Chose the corresponding number of the COM port. Switch the 10bit, 11bit selection switch to 11 bit. The baud rate of the PC/PPI+ cable is adaptive from 0 to 115.2kpbs. There is no need to set that.&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;2&amp;#12289;The long-distance communications between PLC and computer&amp;#65306;&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; When having long-distance communications, the PC / PPI + requires additional external power and we should parallel 120&amp;Omega;i end resistance n between the 3, 8 of RS485 plugs to eliminate signal reflection, as shown below:&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;3&amp;#12289; long-distance communications between the PLC and computer via telephone lines:&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; You have to make a cross-adapter by yourself when you get the PC/PPI+&amp;rsquo;s RS232 port and the MODEM connected. Switch to the corresponding location according to the MODEM that it is 10 or 11.&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; 10 bits MODEM refers: 1 outset bit, 8 data bits, no parity bit, and 1 stop bit(or 7 data bits,1 parity bit).This kind of MODEM is comparative common on the market.&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; 11 bits MODEM refers: 1 outset bit, 8 data bits, 1 parity bit (Occasionally bit check), and 1 stop bit .&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&lt;img alt=&quot;&quot; src=&quot;/upload/images/Kollewin/Siemens%20Accessories/PC-PPI%2B-33.jpg&quot; style=&quot;width: 515px; height: 251px;&quot; /&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&amp;nbsp;&lt;/p&gt;</description>
                <guid isPermaLink="true">https://oxid4.swd.de/oxid/Products-oxid/Hardware/Fieldbus-Hardware/KOL-PC-PPI-oxid.html</guid>
                            </item>
                    <item>
                <title>KOL-USB/PPI 76,00 ¤</title>
                <link>https://oxid4.swd.de/oxid/Products-oxid/Hardware/Fieldbus-Hardware/KOL-USB-PPI-oxid.html</link>
                <pubDate>Thu, 06 Mar 2014 15:44:59 +0100</pubDate>
                <description>&lt;img src=&#039;https://oxid4.swd.de/oxid/out/pictures/generated/product/1/150_150_75/USB-PPI-1.jpg&#039; border=0 align=&#039;left&#039; hspace=5&gt;&lt;h1 class=&quot;productGeneral&quot; id=&quot;productName&quot; style=&quot;margin: 0.3em; font-size: 13px; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;strong style=&quot;color:#B22222;font-size:16px;&quot;&gt;USB/PPI:programming cable for S7-200PLC&lt;/strong&gt;&lt;/h1&gt;

&lt;p&gt;USB/PPI interface,programming cable for Siemens S7-200PLC ,3 meters,with communication indicator,can replace 6ES7 901-3DB30-0XA0,the largest communication distance of up to 2 kilometers.Not support multi-master station&lt;br /&gt;
communication.&lt;br /&gt;
&lt;br /&gt;
Not isolated,so it doesn&amp;#39;t support hot plug,if need isolated cable,pls choose USB/PPI+,you can click the following website for USB/PPI+:&lt;/p&gt;

&lt;p&gt;&lt;a href=&quot;http://swd.de/oxid/de/Produkte/Produktassistent/KOL-USB-PPI.html?listtype=search&amp;amp;searchparam=USB%2FPPI%2B&quot;&gt;http://swd.de/oxid/de/Produkte/Produktassistent/KOL-USB-PPI.html?listtype=search&amp;amp;searchparam=USB%2FPPI%2B&lt;/a&gt;&lt;br /&gt;
&amp;nbsp;&lt;/p&gt;

&lt;p&gt;USB/PPI programming cable simulates USB port as traditional serial port (usually COM3), which enables existing programming software(STEP 7-MicroWin) to communicate through simulated traditional port and PLC devices.&lt;br /&gt;
&lt;br /&gt;
The working power of this cable is from USB port,not provided by the communication port of PLC.The LED of the adapter indicates the sending and receiving status of data.&lt;br /&gt;
USB/PPI is applied to Siemens S7-200 PLC,NOT support hot plug.For the industry scene of strong interference and easily destroying communication port,pls choose optoelectronic isolated USB/PPI+ programming cable.&lt;/p&gt;

&lt;p&gt;&lt;strong style=&quot;color: rgb(50, 67, 74); font-family: tahoma, arial, helvetica, sans-serif; font-size: 16px; line-height: 31px;&quot;&gt;Outline configuration:&lt;/strong&gt;&lt;/p&gt;

&lt;p&gt;&lt;img alt=&quot;&quot; src=&quot;/upload/images/Kollewin/Siemens%20Accessories/USB-PPI-22.jpg&quot; style=&quot;width: 507px; height: 246px;&quot; /&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;Features and technological index:&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679;&amp;nbsp;Support USB/PPI operating system: Windows2000/XP (WinNT4/95/98/Me/DOS not included )&amp;nbsp;&lt;br /&gt;
&amp;#9679; Support USB/PPI programming software version: STEP7 Micro / WIN V3.2 and above.&amp;nbsp;&lt;br /&gt;
&amp;#9679;&amp;nbsp;Fully compatible with USB V1.1 norms and USB CDC V1.1&amp;nbsp;&lt;br /&gt;
&amp;#9679; USB-bus powered, with current consumption is 50 mA&amp;nbsp;&lt;br /&gt;
&amp;#9679; Baud rate: 300 bps ~ 1Mbps automatically adapt to the standard baud rate&amp;nbsp;&lt;br /&gt;
&amp;#9679; Support UART data format: data bits: 7-8; stop bit: 1, 2; check-bit: odd / even / no parity&amp;nbsp;&lt;br /&gt;
&amp;#9679;&amp;nbsp;Support long-distance communications, the largest communications is two kilometers (9600 bps)&amp;nbsp;&lt;br /&gt;
&amp;#9679; Each PC only supports one USB cable programming&amp;nbsp;&lt;br /&gt;
&amp;#9679; Working temperature: -20 ~ +75 &amp;#8451;&amp;nbsp;&lt;br /&gt;
&amp;#9679; Cable length: 3m; Color: black&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;Usage:&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;nbsp;USB device drivers should be installed before using USB/PPI programming cable.&amp;nbsp;&amp;nbsp;&amp;nbsp; After completing Driver installation, the corresponding COM port for the USB/PPI &amp;nbsp;programming cable will be displayed in the &amp;ldquo;Device Manager&amp;rdquo; of Window. The step next is just to choose this COM port in the programming software and other application software and keep other communication parameters as in the Default settings. And the following steps are exactly the same as in the traditional programming cables with RS232 interfaces. Here are requested to indicate that &amp;quot;USB&amp;quot; option in the local communications interface setting which the software is not support to the programming cable.&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; If the COM port in the programming software with &amp;quot;*&amp;quot; symbols, such as &amp;quot;* COM3&amp;quot;, it&amp;rsquo;s shown that the COM port have faults. Quit the software and plug a USB plug or re-install the USB driver.&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; This cable do not support the 187.5 Kbps baud rate as the same with the Siemens PC / PPI programming cable which with the RS232 interfaces.&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; Please note that Siemens COM port in programming software is up to support the option to COM8.But the ports more than COM8 are able to choose but in fact can not be used!&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;Long-distance communication:&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; The largest communications range between the USB/PPI and PLC are up to 2 kilometers (9600 bps),when external plus terminals 120 ohm resistance is needed to connect between the pin3 and pin8 of the RS485 ports (DB9 Male) to eliminate signal reflection. And a PFB-G Bus Isolators is needed to install at the end of PLC. 0.22 mm2 or more unshielded twisted pair lines are used for Communications. When the distance is Over 2,000m, a RS485 repeaters (model: E485GP), can be installed for extending the distance.&lt;/span&gt;&lt;/p&gt;</description>
                <guid isPermaLink="true">https://oxid4.swd.de/oxid/Products-oxid/Hardware/Fieldbus-Hardware/KOL-USB-PPI-oxid.html</guid>
                            </item>
                    <item>
                <title>KOL-USB/PPI+ 76,00 ¤</title>
                <link>https://oxid4.swd.de/oxid/Products-oxid/Hardware/Fieldbus-Hardware/KOL-USB-PPI.html</link>
                <pubDate>Thu, 06 Mar 2014 15:47:20 +0100</pubDate>
                <description>&lt;img src=&#039;https://oxid4.swd.de/oxid/out/pictures/generated/product/1/150_150_75/USB-PPI-plus-1.jpg&#039; border=0 align=&#039;left&#039; hspace=5&gt;&lt;h1 class=&quot;productGeneral&quot; id=&quot;productName&quot; style=&quot;margin: 0.3em; font-size: 13px; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;strong style=&quot;color:#B22222;font-size:16px;&quot;&gt;USB/PPI+:optoelectronic isolated USB/PPI adapter&lt;/strong&gt;&lt;/h1&gt;

&lt;p&gt;&amp;nbsp;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;img alt=&quot;&quot; src=&quot;/upload/images/Kollewin/Siemens%20S7%20200%20Adapter/Usb-PPi%2B1.jpg&quot; style=&quot;width: 189px; height: 200px;&quot; /&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&amp;nbsp;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;optoelectronic isolated USB/PPI adapter,can replace:6ES7 901-3DB30-0XA0,the largest communication distance of up to 2 kilometers.Not support multimaster station communication.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&lt;strong&gt;Summary:&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; USB/PPI+ is the programming cable in which USB interface provided the serial connection, RS485 signal conversion and PPI protocol conversion. Under the control of computer-driven driver, the programming cable makes it possible for the computer&amp;#39;s USB interface to simulate the traditional serial (known as COM interface), thus various existing programming software such as communications software, monitoring software and other applications can be normally used. The working power supply of this cable is directly from the USB port and the programming port of the PLC. The two-color LED on the converter box indicates data&amp;rsquo;s transceiving status.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&amp;nbsp;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&lt;strong&gt;Outline configuration:&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;img alt=&quot;&quot; src=&quot;/upload/images/Kollewin/Siemens%20S7%20200%20Adapter/USB-PPI%2B-2.gif&quot; style=&quot;line-height: 2; width: 555px; height: 160px;&quot; /&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;img alt=&quot;&quot; src=&quot;/upload/images/Kollewin/Siemens%20S7%20200%20Adapter/USBPPI%2B.jpg&quot; style=&quot;width: 550px; height: 302px;&quot; /&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&amp;nbsp;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family: Tahoma; line-height: 26px; text-align: -webkit-center;&quot;&gt;signals definition of the RS485-Block (DB9M) of the USB/PPI+&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;

&lt;table border=&quot;1&quot; cellpadding=&quot;1&quot; cellspacing=&quot;1&quot; class=&quot;tableSWD&quot; style=&quot;width: 500px;&quot;&gt;
	&lt;tbody&gt;
		&lt;tr&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;pins&lt;/span&gt;&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;signal&lt;/span&gt;&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;Description&lt;/span&gt;&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;3&lt;/span&gt;&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;RxD/TxD+&lt;/span&gt;&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family: Tahoma; line-height: 26px;&quot;&gt;Data Line B (RS485 signal positive)&lt;/span&gt;&lt;/span&gt;&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;8&lt;/span&gt;&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;RxD/TxD-&lt;/span&gt;&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family: Tahoma; line-height: 26px;&quot;&gt;Data Line A (RS485 signal negative)&lt;/span&gt;&lt;/span&gt;&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;7&lt;/span&gt;&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;P24V&lt;/span&gt;&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family: Tahoma; line-height: 26px;&quot;&gt;24V power positive&lt;/span&gt;&lt;/span&gt;&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;2&lt;/span&gt;&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;M24V&lt;/span&gt;&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family: Tahoma; line-height: 26px;&quot;&gt;24V power negative(RS485 logic ground)&lt;/span&gt;&lt;/span&gt;&lt;/td&gt;
		&lt;/tr&gt;
	&lt;/tbody&gt;
&lt;/table&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&amp;nbsp;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color: black; font-size: 14px; line-height: 2;&quot;&gt;Features and technological index:&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679; Support USB/PPI+ operating system: Windows2000/XP (WinNT4/95/98/Me/DOS not included )&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679; Support USB/PPI+ programming software version: STEP7 Micro / WIN V3.2 and above.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679; Fully compatible with USB V1.1 norms and USB CDC V1.1&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679;&amp;nbsp;USB bus powered and PLC programming port 24 V power supply&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679;&amp;nbsp;Optical isolation voltage: 1000 VDC ((up to 3000 VDC, it should be declared when making an order)&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679; Baud rate: 300 bps ~ 1Mbps automatically adapt to the standard baud rate&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679; Support UART data format: data bits: 7-8; stop bit: 1, 2; check-bit: odd / even / no parity&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679; Support long-distance communications, the largest communications is two kilometers (9600 bps)&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679; Each PC only supports one USB cable programming&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679; Working temperature: -20 ~ +75 &amp;#8451;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679; Cable length: 3m; Color: black&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;Usage:&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; USB device drivers should be installed before using USB/PPI+ programming cable.&amp;nbsp;&amp;nbsp;&amp;nbsp; After completing Driver installation, the corresponding COM port for the USB/PPI+ &amp;nbsp;programming cable will be displayed in the &amp;ldquo;Device Manager&amp;rdquo; of Window. The step next is just to choose this COM port in the programming software and other application software and keep other communication parameters as in the Default settings. And the following steps are exactly the same as in the traditional programming cables with RS232 interfaces. Here are requested to indicate that &amp;quot;USB&amp;quot; option in the local communications interface setting which the software is not support to the programming cable.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; If the COM port in the programming software with &amp;quot;*&amp;quot; symbols, such as &amp;quot;* COM3&amp;quot;, it&amp;rsquo;s shown that the COM port have faults. Quit the software and plug a USB plug or re-install the USB driver.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; This cable do not support the 187.5 Kbps baud rate as the same with the Siemens PC / PPI programming cable which with the RS232 interfaces.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; Please note that Siemens COM port in programming software is up to support the option to COM8.But the ports more than COM8 are able to choose but in fact can not be used!&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&amp;nbsp;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;Long-distance communications:&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; The largest communications range between the USB/PPI+ and PLC are up to 2 kilometers (9600 bps),when external plus terminals 120 ohm resistance is needed to connect between the pin3 and pin8 of the RS485 ports (DB9 Male) to eliminate signal reflection, but also a 24 VDC power between the pin2 and pin7. And a PFB-G Bus Isolators is needed to install at the end of PLC. 0.22 mm2 or more unshielded twisted pair lines are used for Communications. When the distance is Over 2,000m, a RS485 repeaters can be installed for extending the distance.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;Please Note: USB interface cable cannot be extended.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;img alt=&quot;&quot; src=&quot;/upload/images/Kollewin/Siemens%20S7%20200%20Adapter/Usb-PPi%2B-3.jpg&quot; style=&quot;width: 554px; height: 408px;&quot; /&gt;&lt;/p&gt;</description>
                <guid isPermaLink="true">https://oxid4.swd.de/oxid/Products-oxid/Hardware/Fieldbus-Hardware/KOL-USB-PPI.html</guid>
                            </item>
                    <item>
                <title>KOL-USB/PPIM+ 112,00 ¤</title>
                <link>https://oxid4.swd.de/oxid/Products-oxid/Hardware/Fieldbus-Hardware/KOL-USB-PPIM.html</link>
                <pubDate>Sun, 13 Dec 2015 22:29:33 +0100</pubDate>
                <description>&lt;img src=&#039;https://oxid4.swd.de/oxid/out/pictures/generated/product/1/150_150_75/USB-PPIM-plus.jpg&#039; border=0 align=&#039;left&#039; hspace=5&gt;&lt;h1 class=&quot;productGeneral&quot; id=&quot;productName&quot; style=&quot;margin: 0.3em; font-size: 13px; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;strong style=&quot;color:#B22222;font-size:16px;&quot;&gt;USB/PPIM+:isolated S7-200PLC multi-master station PPI programming&lt;/strong&gt;&lt;/h1&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&amp;nbsp;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;img alt=&quot;&quot; src=&quot;/upload/images/Kollewin/Siemens%20S7%20200%20Adapter/USB-PPIM%2B-1.jpg&quot; style=&quot;width: 192px; height: 200px;&quot; /&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&amp;nbsp;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;optoelectronic isolated USB Siemens S7-200PLC multi-master station PPI programming cable,directly use the STEP7 MicroWIN software to communicate,no need to install driver,support PPI,multi-master station PPI and advanced PPI,support 187.5Kbps high speed communication,just the same as 6ES7 901-3DB30-0XA0,3 meters,with communication indicator.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&lt;strong&gt;Summary:&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; USB / PPIM + is the PPI Multi-Master programming Cable which with USB interface, to realize the level conversion and various of PPI protocol conversion from USB to RS485.Many cheap USB / PPI cable on the market simulate USB to virtual serial (COM port) to realize the communications, it&amp;rsquo;s commonly known as &amp;quot;pseudo-USB interface&amp;quot;. The cable only convert the level from USB to RS485, can only support the normal PPI Protocol. But the USB / PPIM + is the real USB interface cable, without installing drivers, directly use the USB option in STEP7 Micre / WIN software, support PPI, Advanced PPI,and Multiple Master Network Protocol. The cable support the 187.5 Kbps high-speed communications, and take charge of the Multiple Master Network.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; This cable is 100% compatible with Siemens PPI Multi-Master USB Cable 6 ES7 901-3DB30-0XA0, and the only difference is that the work power supply from the computer&amp;#39;s USB port through the DC / DC isolation, no longer powered by the PLC port. It&amp;rsquo;s easy to extend communications distance of the RS485 without considering the power supply. The two-color LED on the converter box indicates data&amp;rsquo;s transceiving status.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; USB/PPIM+ is designed for industrial-type photoelectric isolation cable. USB port and RS485 ports are equipped with surge protection and anti-lightning protection circuitry, which can be Hot plug. It&amp;rsquo;s applicable to the entire Siemens S7-200 Series PLC It&amp;rsquo;s particularly suited to the industrial scene which the communications interface is more easily damaged because of the greater interference. The protection circuit ensures the safe operation of the system.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&lt;strong&gt;Outline configuration:&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;img alt=&quot;&quot; src=&quot;/upload/images/Kollewin/Siemens%20S7%20200%20Adapter/USB-PPIM%2B-2.jpg&quot; style=&quot;width: 502px; height: 255px;&quot; /&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family: Tahoma; line-height: 26px; text-align: -webkit-center;&quot;&gt;signals definition of the RS485-Block (DB9M) of the USB/PPIM+&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;

&lt;table border=&quot;1&quot; cellpadding=&quot;1&quot; cellspacing=&quot;1&quot; style=&quot;width: 500px;&quot;&gt;
	&lt;tbody&gt;
		&lt;tr&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;pin&lt;/span&gt;&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;signal&lt;/span&gt;&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;Description&lt;/span&gt;&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;3&lt;/span&gt;&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;RxD/TxD+&lt;/span&gt;&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;Data Line B (RS485 signal positive)&lt;/span&gt;&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;8&lt;/span&gt;&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;RxD/TxD-&lt;/span&gt;&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;Data Line A (RS485 signal negative)&lt;/span&gt;&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;5&lt;/span&gt;&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;GND&lt;/span&gt;&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;DGND&lt;/span&gt;&lt;/td&gt;
		&lt;/tr&gt;
	&lt;/tbody&gt;
&lt;/table&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&amp;nbsp;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;strong&gt;Features and technological index:&lt;/strong&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&amp;#9679; support USB / PPIM + operating system: Windows2000/Windows XP&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&amp;#9679; support USB / PPIM + programming software version: STEP7 Micro / WIN V4.0 and above, without installing drivers, directly use the USB option in Local Connection.&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&amp;#9679; USB is fully compatible with USB V1.1 norms and USB V2.0&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&amp;#9679; USB bus-powered, 5 VDC, the power consumption is about 100 mA, with over current protection&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&amp;#9679; optical isolation voltage: 1000 VDC (up to 3000 VDC, it should be declared when making an order)&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&amp;#9679; USB port with anti-surge protection, RS485 port with 500 W anti-lightning protection and over current protection&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&amp;#9679; support PPI baud rate: 9.6 Kbps, 19.2Kbps, 187.5Kbps&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&amp;#9679; support the communication protocol: PPI, senior PPI, multi-master PPI.&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&amp;#9679; support long-distance communications, the largest communications distance is 2,000 meters (9.6 Kbps) or 1 km(187.5Kbps).&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&amp;#9679; each PC only supports a USB cable programming&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&amp;#9679; temperature: -20 ~ +75 &amp;#8451;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&amp;#9679; Cable length: three meters, colors: black&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;Usage:&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;1,&amp;nbsp;Enter STEP7 Micro / WIN programming software and click &amp;quot;Settings PG / PC interface&amp;quot;, check the &amp;quot;PC / PPI cable (PPI)&amp;quot; and click &amp;quot;Properties&amp;hellip;&amp;quot; button.&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;2,Select &amp;quot;USB&amp;quot; option in &amp;quot;Local Connection&amp;quot;.&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;3,&amp;nbsp;Set up the Station Parameters settings in &amp;quot;PPI&amp;quot; as following: Address: 0, Timeout: 1s .&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;Set up the Network Parameters in &amp;quot;PPI&amp;quot; in accordance with the needs of you. You can choose any of the following:&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;Advanced PPI: check the Advanced PPI.&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;Multiple Master Network: check Multiple Master Network.&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;General PPI: do not check any of option, which is the default option.&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;select a baud rate as the same with the PLC. If you do not know that the PLC baud rate can be arbitrary choice one.&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;Click &amp;quot;OK&amp;quot; button to return to the main menu interface.&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;4,&amp;nbsp;click on the main menu interface of &amp;quot;communication&amp;quot; button to enter the PLC interface connection, check the &amp;quot;search all baud rate&amp;quot; box, and then double-click on the &amp;quot;Double-click refresh&amp;rdquo;. After a while of searching ,the PLC model And address and other information will display on the software, it&amp;rsquo;s means that connect successfully with the PLC. Click the &amp;quot;confirmation&amp;quot; button to conduct upload, download, and other operating.&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;img alt=&quot;&quot; src=&quot;/upload/images/Kollewin/Siemens%20S7%20200%20Adapter/USB-PPIM%2B-3.jpg&quot; style=&quot;width: 554px; height: 382px;&quot; /&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&amp;nbsp;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&lt;b style=&quot;color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;PPI Multi-Master Cable of&amp;nbsp;USB/PPIM+ no longer support the early version of the low CPU21X series PLC.&lt;/b&gt;&lt;/span&gt;&lt;b style=&quot;font-size: 14px; line-height: 13px;&quot;&gt;PPI Multi-Master Cable of&amp;nbsp;USB/PPIM+&amp;nbsp;do not support&amp;nbsp;Freeport&amp;nbsp;communication and MODEM communication.&lt;/b&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&lt;b style=&quot;color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;Long-distance communications:&lt;/b&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&lt;b style=&quot;color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; The largest communications range between the USB/PPIM+ and PLC are up to 2 kilometers (9.6K bps) or 1 km(187.5Kbps),when external plus terminals 120 ohm resistance is needed to connect between the pin3 and pin8 of the RS485 ports (DB9 Male) to eliminate signal reflection. And a PFB-G Bus Isolators is needed to install at the end of PLC. 0.22 mm2 or more unshielded twisted pair lines are used for Communications. When the distance is longer than the length of cable, a RS485 repeaters (model: E485GP), can be installed in the bus for extending the distance.&lt;/b&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&lt;b style=&quot;color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; Because the power of USB / PPIM + all supplied from the USB ports of the computer, you do not need to consider power su&lt;/b&gt;&lt;b style=&quot;color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;pply when extended the length of cable.&lt;/b&gt;&lt;b style=&quot;color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt; &amp;nbsp;It&amp;rsquo;s better than the similar products of Siemens.&lt;/b&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&lt;b style=&quot;color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; Please Note: USB interfac&lt;/b&gt;&lt;b style=&quot;color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;e cable cannot be extended.&lt;/b&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; line-height: 2;&quot;&gt;&lt;img alt=&quot;&quot; src=&quot;/upload/images/Kollewin/Siemens%20S7%20200%20Adapter/USB-PPIM%2B-4.jpg&quot; style=&quot;width: 513px; height: 378px;&quot; /&gt;&lt;/p&gt;</description>
                <guid isPermaLink="true">https://oxid4.swd.de/oxid/Products-oxid/Hardware/Fieldbus-Hardware/KOL-USB-PPIM.html</guid>
                            </item>