<?xml version="1.0" encoding="ISO-8859-15" ?>
<rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom">
<channel>
                <title>SWD.de/+ Manufacturer +/Kollewin Technology Co., Ltd./KOL-Siemens S7-300, S7-400 Adapter, MPI Cable for SIMATIC S7-300/S7-400 PLC products</title>
        <link>https://oxid4.swd.de/oxid/Manufacturer/Kollewin-Technology-Co-Ltd/KOL-Siemens-S7-300-S7-400-Adapter-MPI-Cable-for-SIMATIC-S7-300-S7-400-PLC/</link>
        <description>KOL-Siemens S7-300, S7-400 Adapter, MPI Cable for SIMATIC S7-300/S7-400 PLC category's articles</description>
        <language>en</language>
        <copyright>SWD.de</copyright>
        <lastBuildDate>Mon, 31 Jan 2022 17:32:13 +0100</lastBuildDate>
        <generator>SWD.de</generator>
                    <managingEditor>order@swd.de (Uwe Wannags)</managingEditor>
                        <image>
            <url>https://oxid4.swd.de/oxid/out/swd/img/logo.png</url>
            <title>SWD.de/+ Manufacturer +/Kollewin Technology Co., Ltd./KOL-Siemens S7-300, S7-400 Adapter, MPI Cable for SIMATIC S7-300/S7-400 PLC products</title>
            <link>https://oxid4.swd.de/oxid/Manufacturer/Kollewin-Technology-Co-Ltd/KOL-Siemens-S7-300-S7-400-Adapter-MPI-Cable-for-SIMATIC-S7-300-S7-400-PLC/</link>
        </image>
        
        <atom:link href="https://oxid4.swd.de/oxid/rss/Category/KOL-Siemens-S7-300-S7-400-Adapter-MPI-Cable-for-SIMATIC-S7-300/S7-400-PLC/" rel="self" type="application/rss+xml" />
                    <item>
                <title>KOL-USB Adapter CN 137,00 ¤</title>
                <link>https://oxid4.swd.de/oxid/Products-oxid/Hardware/Fieldbus-Hardware/KOL-USB-Adapter-CN.html</link>
                <pubDate>Tue, 02 Jun 2015 14:23:09 +0200</pubDate>
                <description>&lt;img src=&#039;https://oxid4.swd.de/oxid/out/pictures/generated/product/1/150_150_75/USB Adapter CN.jpg&#039; border=0 align=&#039;left&#039; hspace=5&gt;&lt;h1 class=&quot;productGeneral&quot; id=&quot;productName&quot; style=&quot;line-height: 13px; margin: 0.3em; font-size: 13px; color: rgb(50, 67, 74); font-family: Tahoma;&quot;&gt;&lt;span style=&quot;color: rgb(255, 0, 0);&quot;&gt;&lt;span style=&quot;font-size: 16px;&quot;&gt;&lt;strong&gt;USB ADAPTER CN:support PC USB to PROFIBUS/MPI/PPI communication&lt;/strong&gt;&lt;/span&gt;&lt;/span&gt;&lt;/h1&gt;

&lt;div align=&quot;left&quot; class=&quot;categoryIcon&quot; id=&quot;categoryIcon&quot; style=&quot;color: rgb(50, 67, 74); font-family: Tahoma; font-size: 11px; line-height: 13px;&quot;&gt;&lt;a href=&quot;http://www.elec-intro.com/shop/-c-.html&quot; style=&quot;color: rgb(233, 33, 0); text-decoration: none;&quot;&gt;Siemens&lt;/a&gt;&lt;/div&gt;

&lt;div class=&quot;centeredContent back&quot; id=&quot;productMainImage&quot; style=&quot;float: left; margin: 0em 1em 1em 0em; color: rgb(50, 67, 74); font-family: Tahoma; font-size: 11px; line-height: 13px;&quot;&gt;&lt;img alt=&quot;USB-Adapter CN: Unterstützung PC USB an PROFIBUS / MPI / PPI-Kommunikation&quot; src=&quot;/upload/images/Kollewin/Siemens%20S7%20200%20Adapter/USB%20Adapter%20CN(1).jpg&quot; style=&quot;color: rgb(50, 67, 74); font-family: Tahoma; font-size: 11px; line-height: 13px; border: none; width: 200px; height: 175px;&quot; title=&quot; USB-Adapter CN: Unterstützung PC USB an PROFIBUS / MPI / PPI-Kommunikation &quot; /&gt;&lt;a style=&quot;color: rgb(233, 33, 0);&quot;&gt;&lt;br /&gt;
&lt;span class=&quot;imgLink&quot;&gt;larger image&lt;/span&gt;&lt;/a&gt;&lt;/div&gt;

&lt;h1 class=&quot;productGeneral&quot; id=&quot;productName&quot; style=&quot;margin: 0.3em; font-size: 13px; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color:#FF0000;&quot;&gt;USB ADAPTER CN:support PC USB to PROFIBUS/MPI/PPI communication&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h1&gt;

&lt;h2 class=&quot;productGeneral&quot; id=&quot;productPrices&quot; style=&quot;margin: 0.3em; font-size: 13px; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&amp;nbsp;&lt;/h2&gt;

&lt;div class=&quot;productGeneral biggerText&quot; id=&quot;productDescription&quot; style=&quot;font-size: 1.2em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;a style=&quot;color: rgb(233, 33, 0);&quot;&gt;&lt;br /&gt;
The differences with USB/MPI+ V4.0 are as follows:&lt;br /&gt;
(1)support Win7 64bits&lt;br /&gt;
(2)Supoort Step7 V5.5 and above&lt;br /&gt;
(3)Support main profibus function&lt;br /&gt;
1.don&amp;#39;t support one PC communicate with several PLCs at&lt;br /&gt;
the same time.&lt;br /&gt;
2.don&amp;#39;t support several PCs communicate with one&lt;br /&gt;
PLC at the same time.&lt;br /&gt;
&lt;br /&gt;
USB Adapter CN is a high-tech adapter similar , support USB of computer to PROFIBUS/MPI/PPI communication, USB Adapter CN adopt power supply from USB port,use the low-power low-voltage chip,even if the USB port power low down to 4V&amp;#65292;it still can ensure the stable and reliable work of the adapter. RS485 interface(PROFIBUS/MPI/PPI) of USB Adapter CN is the standard interface as same as the CP5611/CP5512, the 6PIN and 5PIN of DB9F socket output 5VDC power which can supply the power for the termination resistors. It&amp;#39;s used for Siemens S7-200/300/400 PLC programming.&lt;br /&gt;
&lt;br /&gt;
Main Technical Specifications:&lt;br /&gt;
&amp;#9679; Compatible with USB V1.1 and USB V2.0 specifications,connect the USB port of PC to DP/MPI/PPI interface of S7 system.&lt;br /&gt;
&amp;#9679; Support PROFIBUS/MPI/PPI communication,auto bus protocol test&lt;br /&gt;
&amp;#9679; You can download the latest software from Siemens website to update the firmware for USB Adapter CN to get the latest function&lt;br /&gt;
&amp;#9679; Power supply from USB port, power consumption about 150mA,with over current and surge protection&lt;br /&gt;
&amp;#9679; Opto-isolated voltage 1000VDC.&lt;br /&gt;
&amp;#9679; USB port has the anti-surging protection&lt;br /&gt;
&amp;#9679; RS485 interface has the anti-lightning and surging protector, Repeatability surge capacity: Ipp=100A&amp;#65288;10/700us&amp;#65292;4KV&amp;#65289;,meet the standard ITU-TK20/21&amp;#12289;VDE 0433. &amp;plusmn;15KV ESD protection.&lt;br /&gt;
&amp;#9679; support long distance communication,the largest communication distance meet the profibus standard&lt;br /&gt;
&amp;#9679; With the power indicator, USB indicator, DP/MPI indicator.&lt;br /&gt;
&amp;#9679; One PC only support one USB Adapter CN&lt;br /&gt;
&amp;#9679; Can install the adapter on the S7-300/400PLC rail or 35MM standard rail.&lt;br /&gt;
&amp;#9679; Overall Size: 123mm&amp;times;68mm&amp;times;30mm(Length*Width*Height),with the mounting bracket&lt;br /&gt;
&amp;#9679; Working Temperature: -20&amp;#65374;+75&amp;#8451;&lt;/a&gt;&lt;/div&gt;</description>
                <guid isPermaLink="true">https://oxid4.swd.de/oxid/Products-oxid/Hardware/Fieldbus-Hardware/KOL-USB-Adapter-CN.html</guid>
                            </item>
                    <item>
                <title>KOL-PC/MPI 129,00 ¤</title>
                <link>https://oxid4.swd.de/oxid/Products-oxid/Hardware/Fieldbus-Hardware/KOL-PC-MPI.html</link>
                <pubDate>Thu, 06 Mar 2014 15:50:10 +0100</pubDate>
                <description>&lt;img src=&#039;https://oxid4.swd.de/oxid/out/pictures/generated/product/1/150_150_75/KOL-PC-MPI.jpg&#039; border=0 align=&#039;left&#039; hspace=5&gt;&lt;h1 class=&quot;productGeneral&quot; id=&quot;productName&quot; style=&quot;margin: 0.3em; font-size: 13px; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;strong style=&quot;color:#B22222;font-size:16px;&quot;&gt;PC/MPI:Siemens S7-300 PLC Programming cable&lt;/strong&gt;&lt;/h1&gt;

&lt;p&gt;&amp;nbsp;&lt;/p&gt;

&lt;p&gt;&lt;img alt=&quot;&quot; src=&quot;/upload/images/Kollewin/Siemens%20S7%20200%20Adapter/PC-MPI.jpg&quot; style=&quot;width: 200px; height: 176px;&quot; /&gt;&lt;/p&gt;

&lt;p&gt;&amp;nbsp;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family: Tahoma; line-height: 13px;&quot;&gt;Siemens S7-300 PLC Programming cable,5 meters.&lt;/span&gt;&lt;br style=&quot;color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot; /&gt;
&lt;br style=&quot;color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot; /&gt;
&lt;br style=&quot;color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot; /&gt;
&lt;span style=&quot;font-family: Tahoma; line-height: 13px;&quot;&gt;Not isolated,so it doesn&amp;#39;t support hot plug,if need isolated cable,pls choose PC/MPI+,you can click the following website for PC/MPI+:&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;a href=&quot;http://swd.de/oxid/Products-oxid/Hardware/Fieldbus-Hardware/KOL-PC-MPI-oxid.html?listtype=search&amp;amp;searchparam=PC%2FMPI%2B&quot;&gt;http://swd.de/oxid/Products-oxid/Hardware/Fieldbus-Hardware/KOL-PC-MPI-oxid.html?listtype=search&amp;amp;searchparam=PC%2FMPI%2B&lt;/a&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family: Tahoma; line-height: 13px;&quot;&gt;PC / MPI adapter is also known as PC adapter. It&amp;rsquo;s physical interface is the conversion from RS232 interfaces to the RS485,including the conversion from RS232 to MPI protocol (MultiPoint Interface).And it is used for the connecting between the PC COM (RS232) and MPI (RS485) of Siemens S7-300PLC.This product is non-isolate, choose PC / MPI + if you need an electro-optical isolation.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;img alt=&quot;&quot; src=&quot;/upload/images/Kollewin/Siemens%20S7%20200%20Adapter/PC-MPI-2.jpg&quot; style=&quot;width: 528px; height: 247px;&quot; /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&amp;nbsp;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&lt;strong&gt;Main technical parameters&amp;#65306;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9733;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; RS232 Port baud rate&amp;#65306;19.2Kbps&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9733;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; MPI Port baud rate&amp;#65306;187.5Kbps&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9733;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; With the data received and sent indicator light&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9733;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; Temperature&amp;#65306;0&amp;#65374;75&amp;#8451;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9733;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; Total length of cable&amp;#65306;5m&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&lt;strong&gt;STEP7 Software settings&amp;#65306;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;1&amp;#12289; Go into STEP7 the main software programming interface&amp;#65288;SIMATIC Manager&amp;#65289;&amp;#65292;click &amp;ldquo;Set PG/PC Interface&amp;hellip;&amp;rdquo; which is under the &amp;ldquo;Options&amp;rdquo; menu, and the get to the PG/PC setting interface&amp;#12290;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;2&amp;#12289; Double-click on &amp;ldquo;PC Adapter&amp;#65288;Auto&amp;#65289;&amp;rdquo;or&amp;ldquo;PC Adapter&amp;#65288;MPI&amp;#65289;&amp;rdquo;to go into the interface setting of parameters of RS232 and the MPI. The adapter does not support &amp;quot;PC Adapter (PROFIBUS)&amp;quot; option.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;3&amp;#12289; Click on the &amp;quot;Local Connection&amp;quot; option to set the interface parameters of RS232, to choose the right computers COM mouth (RS232), change the RS232 communication baud rate to 19200 bps.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;4&amp;#12289; Click the &amp;quot;MPI&amp;quot; option (if it&amp;#39;s on &amp;quot;PC Adapter (MPI)&amp;quot; method) to set MPI interface parameters for the adapter, as the MPI interface of the adapter gets the baud rate fixed at 187.5 Kbps, so here can only be set to 187.5 Kbps.&amp;nbsp;&lt;br /&gt;
If it is &amp;quot;PC Adapter (Auto)&amp;quot; method the choice should be &amp;quot;Address: 0&amp;quot; and &amp;quot;Timeout: 30s&amp;quot;.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&amp;nbsp;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; After the settings above the adapter can be set up on-line communication with the PLC, now you should pay attention to that&amp;nbsp;you shouldn&amp;rsquo;t change the factory default of the MPI port baud rate 187.5Kpbs on the CPU which is under the &amp;ldquo;Network Settings&amp;rdquo;.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; Since the baud rate of the MPI port of the adapter is fixed at 187.5Kbps, if it is set at other figures, the adapter will not work with PLC! Make sure that the baud rate of the MPI port on your S7-300PLC&amp;rsquo;s CPU is fixed at 187.5Kpbs.Otherwise,you have to use the Siemens&amp;#39;s programming communication facility to set that baud rate to 187.5Kpbs,in order to make the adapter work correctly.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;br /&gt;
&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;The quality is guaranteed.It&amp;#39;s tested before shippment.Not made by Siemens,OEM product as the replacement.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
After you place the order on line,pls contact us and we will calculate the freight fee for you according to your requirements.&lt;br /&gt;
&lt;br /&gt;
The item will be delivered within 3-5 working days once payment is received and cleared.Please pay within 3 days after your order.&lt;br /&gt;
&lt;br /&gt;
If you need large quantity(more than 20PCS),Pls contact us and we will give you the competitive wholesale price.&lt;/span&gt;&lt;/p&gt;</description>
                <guid isPermaLink="true">https://oxid4.swd.de/oxid/Products-oxid/Hardware/Fieldbus-Hardware/KOL-PC-MPI.html</guid>
                            </item>
                    <item>
                <title>KOL-PC/MPI+ 127,00 ¤</title>
                <link>https://oxid4.swd.de/oxid/Products-oxid/Hardware/Fieldbus-Hardware/KOL-PC-MPI-oxid.html</link>
                <pubDate>Fri, 07 Mar 2014 15:34:56 +0100</pubDate>
                <description>&lt;img src=&#039;https://oxid4.swd.de/oxid/out/pictures/generated/product/1/150_150_75/PC-MPI-plus-1.jpg&#039; border=0 align=&#039;left&#039; hspace=5&gt;&lt;h1 class=&quot;productGeneral&quot; id=&quot;productName&quot; style=&quot;margin: 0.3em; font-size: 13px; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;strong style=&quot;color:#B22222;font-size:16px;&quot;&gt;PC/MPI+:RS232 isolated Siemens S7-300/400 PLC Programming adapter&lt;/strong&gt;&lt;/h1&gt;

&lt;p align=&quot;left&quot; style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&amp;nbsp;&lt;/p&gt;

&lt;p align=&quot;left&quot; style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;optoelectronic isolated RS232/MPI,Siemens S7-300/400 PLC Programming adapter cable,with communication indicator,can replace Siemens 6ES7 972-0CA23-0XA0,automatically adjust the communication speed from 19.2Kbps to 115.2Kbps for the PC port,automatically adjust the communication speed from 19.2Kbps to 187.5Kbps for the MPI interface.Can connect PLC and the touch panel of third party factory to communicate.It doesn&amp;#39;t support profibus function.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&amp;nbsp;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;nbsp;&amp;nbsp; PC/MPI+ adapter, or named PC adapter, could achieve the level conversion of RS232 to RS485 and the protocal conversion of RS232 to MPI(MultiPoint Interface).&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; PC/MPI+ is the adapter of photoelectric isolation type towards industrial design. Between RS232 port and RS485 port exist the surge protection and anti-lightning protection circuit, adaptable to the full PLC series of Siemens S7-300/400 and those devices with MPI port, especially the industrial fields with greater interference and easily damaged communication port. All kinds of protection measures in the circuit give promission to the safe operation of the system.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color: rgb(0, 0, 0); font-family: Tahoma; font-size: 14px; line-height: 28px;&quot;&gt;PC/MPI+ can make touch-screen communications with the third party under the link of S7-300/400PLC, such as eView, Wei-lun and kun-lun state.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;nbsp; &amp;nbsp;&lt;/span&gt;&lt;img alt=&quot;&quot; src=&quot;/upload/images/Kollewin/Siemens%20S7%20200%20Adapter/PCMPI%2B-2.jpg&quot; style=&quot;opacity: 0.9; color: rgb(0, 0, 0); font-size: 14px; line-height: 28px; width: 553px; height: 282px;&quot; /&gt;&lt;span style=&quot;color: black; font-size: 14px; line-height: 2;&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;Characteristics and main technical parametres:&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&amp;#9733; Power: It is supplied by the 24VDC MPI port of PLC, power consumption of about 1w, with overcurrent protection and surge protection.&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&amp;#9733; Isolation Voltage: 1000VDC(Maximun to 3000 VDC, orders require statement.)&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&amp;#9733; RS232 port has anti-surge protection, RS485 port has anti-lightning protection and overcurrent protection with the consumption of 500w.&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&amp;#9733; RS232 port baud rate: 19.2Kbps---115.2Kbps, automatically adaptable to the standard baud rate.&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&amp;#9733; MPI port baud rate: 187.5Kbps---19.2Kbps, automatically adaptable.&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&amp;#9733; Supporting the connection of PLC to touch-screen communication with the third party.&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&amp;#9733; With a power indicater light, on-line and data transmission indicater light.&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&amp;#9733; Working temperature: -20&amp;#65374;75&amp;#8451;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&amp;#9733; Dimension: 103&amp;times;50&amp;times;26; After connecting the RS232 cables: 5.5m.&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;RS232 adapter port and port-pin RS485 signal definations:&lt;/p&gt;

&lt;p align=&quot;center&quot; style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;RS232-Block(DB9M) defination signals&amp;nbsp;&lt;/p&gt;

&lt;table border=&quot;1&quot; cellpadding=&quot;1&quot; cellspacing=&quot;1&quot; class=&quot;tableSWD&quot; style=&quot;width: 500px;&quot;&gt;
	&lt;tbody&gt;
		&lt;tr&gt;
			&lt;td&gt;number&lt;/td&gt;
			&lt;td&gt;name&lt;/td&gt;
			&lt;td&gt;Instructions&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td&gt;1&lt;/td&gt;
			&lt;td&gt;DCD&lt;/td&gt;
			&lt;td&gt;No use&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td&gt;2&lt;/td&gt;
			&lt;td&gt;RXD&lt;/td&gt;
			&lt;td&gt;RS232 signal reception&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td&gt;3&lt;/td&gt;
			&lt;td&gt;TXD&lt;/td&gt;
			&lt;td&gt;RS232 signal sending&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td&gt;4&lt;/td&gt;
			&lt;td&gt;DTR&amp;nbsp;&lt;/td&gt;
			&lt;td&gt;Short circuit with No.6&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td&gt;5&lt;/td&gt;
			&lt;td&gt;GND&lt;/td&gt;
			&lt;td&gt;RS232 signal to ground&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td&gt;6&lt;/td&gt;
			&lt;td&gt;DSR&lt;/td&gt;
			&lt;td&gt;Short cut with No.4&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td&gt;7&lt;/td&gt;
			&lt;td&gt;RTS&lt;/td&gt;
			&lt;td&gt;Sending requsts&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td&gt;8&lt;/td&gt;
			&lt;td&gt;CTS&lt;/td&gt;
			&lt;td&gt;Sending clear&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td&gt;9&lt;/td&gt;
			&lt;td&gt;RI&lt;/td&gt;
			&lt;td&gt;No use&lt;/td&gt;
		&lt;/tr&gt;
	&lt;/tbody&gt;
&lt;/table&gt;

&lt;p&gt;&amp;nbsp;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color: rgb(50, 67, 74); font-family: Tahoma; line-height: 26px; text-align: -webkit-center;&quot;&gt;RS485-Block(DB9M) defination signals&lt;/span&gt;&lt;/p&gt;

&lt;table border=&quot;1&quot; cellpadding=&quot;1&quot; cellspacing=&quot;1&quot; class=&quot;tableSWD&quot; style=&quot;width: 500px;&quot;&gt;
	&lt;tbody&gt;
		&lt;tr&gt;
			&lt;td&gt;Pin number&lt;/td&gt;
			&lt;td&gt;Signal name&lt;/td&gt;
			&lt;td&gt;Instructions&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td&gt;1&lt;/td&gt;
			&lt;td&gt;NC&lt;/td&gt;
			&lt;td&gt;No use&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td&gt;2&lt;/td&gt;
			&lt;td&gt;M24V&lt;/td&gt;
			&lt;td&gt;Negtive 24VDC power&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td&gt;3&lt;/td&gt;
			&lt;td&gt;B&lt;/td&gt;
			&lt;td&gt;RS485 positive signal&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td&gt;4&lt;/td&gt;
			&lt;td&gt;RTSAS&lt;/td&gt;
			&lt;td&gt;Data reception control&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td&gt;5&lt;/td&gt;
			&lt;td&gt;GND&lt;/td&gt;
			&lt;td&gt;RS485 signal to ground&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td&gt;6&lt;/td&gt;
			&lt;td&gt;NC&lt;/td&gt;
			&lt;td&gt;No use&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td&gt;7&lt;/td&gt;
			&lt;td&gt;P24V&lt;/td&gt;
			&lt;td&gt;24VDC positive power&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td&gt;8&lt;/td&gt;
			&lt;td&gt;A&lt;/td&gt;
			&lt;td&gt;RS485 negative signal&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td&gt;9&lt;/td&gt;
			&lt;td&gt;RTS_PG&lt;/td&gt;
			&lt;td&gt;Data-send control&lt;/td&gt;
		&lt;/tr&gt;
	&lt;/tbody&gt;
&lt;/table&gt;

&lt;p&gt;&amp;nbsp;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color: rgb(50, 67, 74); font-family: Tahoma; line-height: 26px; text-align: -webkit-center;&quot;&gt;Instructions of the indicater light&lt;/span&gt;&lt;/p&gt;

&lt;table border=&quot;1&quot; cellpadding=&quot;1&quot; cellspacing=&quot;1&quot; class=&quot;tableSWD&quot; style=&quot;width: 500px;&quot;&gt;
	&lt;tbody&gt;
		&lt;tr&gt;
			&lt;td&gt;Indicater light&lt;/td&gt;
			&lt;td&gt;On&lt;/td&gt;
			&lt;td&gt;Qlittering&lt;/td&gt;
			&lt;td&gt;Out&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td&gt;Power&lt;/td&gt;
			&lt;td&gt;Normal&lt;/td&gt;
			&lt;td&gt;Error&lt;/td&gt;
			&lt;td&gt;Error or failing to link to power&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td&gt;Active&lt;/td&gt;
			&lt;td&gt;Online&lt;/td&gt;
			&lt;td&gt;Transmission of data&lt;/td&gt;
			&lt;td&gt;Not online&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td&gt;Tx&lt;/td&gt;
			&lt;td&gt;Error&lt;/td&gt;
			&lt;td&gt;Send data&lt;/td&gt;
			&lt;td&gt;No data transmission&lt;/td&gt;
		&lt;/tr&gt;
	&lt;/tbody&gt;
&lt;/table&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;Software settings of STEP7:&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; Entering the main interface of STEP7 programming software(SIMATIC Manager), clicking on &amp;ldquo;Options&amp;rdquo; menu under the &amp;ldquo;Set PG/PC Interface&amp;hellip;&amp;rdquo; option into the PG/PC interface settings.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;1.&amp;nbsp;&amp;nbsp;&amp;nbsp; Double clicking on &amp;ldquo;PC Adapter(MPI)&amp;rdquo; into the RS232 interfaces and MPI set of parameters. The adapter does not support &amp;ldquo;PC Adapter(PROFIBUS)&amp;rdquo; option.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;2.&amp;nbsp;&amp;nbsp;&amp;nbsp; Clicking on &amp;ldquo;Local Connection&amp;rdquo; option set RS232 interface parameters, choosing PC/MPI to connect on the port of COM correctly, and it will adapt to the chosen baud rate automatically, both 19200bps and 38400bps of RS232 communication.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;3.&amp;nbsp;&amp;nbsp;&amp;nbsp; Clicking &amp;ldquo;MPI&amp;rdquo; to set port parameters of adapter MPI, acceptable at both 187.5Kbps and 19.2Kbps, and the adapter will adapt to its baud rate automatically. Others have already been set.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;4.&amp;nbsp;&amp;nbsp;&amp;nbsp; On-line test accessing point: Using PC/MPI to connect to MPI port and RS232 port of the computer. And then click on the button in the red circle as follow, if appearing the data inside the red line, the test has passed. Then one could operate on it.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&lt;img alt=&quot;&quot; src=&quot;/upload/images/Kollewin/Siemens%20S7%20200%20Adapter/PCMPI%2B-3.jpg&quot; style=&quot;width: 553px; height: 422px;&quot; /&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;The long-distance communication of PC/MPI+ adapter:&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;1. To extend the distance of RS485 port:&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&lt;img alt=&quot;&quot; src=&quot;/upload/images/Kollewin/Siemens%20S7%20200%20Adapter/PCMPI%2B-4.jpg&quot; style=&quot;width: 553px; height: 236px;&quot; /&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family: Tahoma; line-height: 26px;&quot;&gt;2. To extend the distance of RS232 port:&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family: Tahoma; line-height: 26px;&quot;&gt;&lt;img alt=&quot;&quot; src=&quot;/upload/images/Kollewin/Siemens%20S7%20200%20Adapter/PCMPI%2B-5.jpg&quot; style=&quot;width: 554px; height: 278px;&quot; /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family: Tahoma; line-height: 26px;&quot;&gt;RS232 Cable:&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;padding: 0.5em; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 2;&quot;&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family: Tahoma; line-height: 26px;&quot;&gt;&lt;img alt=&quot;&quot; src=&quot;/upload/images/Kollewin/Siemens%20S7%20200%20Adapter/PCMPI%2B-6.jpg&quot; style=&quot;width: 553px; height: 268px;&quot; /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;</description>
                <guid isPermaLink="true">https://oxid4.swd.de/oxid/Products-oxid/Hardware/Fieldbus-Hardware/KOL-PC-MPI-oxid.html</guid>
                            </item>
                    <item>
                <title>KOL-USB/MPI+V2.0 127,00 ¤</title>
                <link>https://oxid4.swd.de/oxid/Products-oxid/Hardware/Fieldbus-Hardware/KOL-USB-MPI-V2-0.html</link>
                <pubDate>Thu, 29 Oct 2015 19:24:12 +0100</pubDate>
                <description>&lt;img src=&#039;https://oxid4.swd.de/oxid/out/pictures/generated/product/1/150_150_75/USB-MPIplusv2-0-bild1.jpg&#039; border=0 align=&#039;left&#039; hspace=5&gt;&lt;h1 class=&quot;productGeneral&quot; id=&quot;productName&quot; style=&quot;margin: 0.3em; font-size: 13px; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;strong style=&quot;color:#B22222;font-size:16px;&quot;&gt;USB/MPI+ V2.0:USB isolated Siemens S7-300/400 PLC adapter&lt;/strong&gt;&lt;/h1&gt;

&lt;p&gt;&amp;nbsp;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;This is USB/MPI+ V2.0 only for Siemens S7-300/400 PLC.Now USB/MPI+ V4.0 is available.USB/MPI+ V4.0 is for Siemens&amp;nbsp;S7-200/300/400 PLC programming adapter,use Siemens original driver.&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;optoelectronic isolated USB/MPI V2.0,Siemens S7-300/400 PLC Programming adapter cable,3 meters,with communication indicator,can replace Siemens 6ES7 972-0CB20-0XA0,automatically adjust the communication speed&amp;nbsp; from 19.2Kbps to 115.2Kbps for the PC port,automatically adjust the communication speed from 19.2Kbps to 187.5Kbps for the MPI interface.It doesn&amp;#39;t support profibus function.&lt;br /&gt;
&lt;br /&gt;
USB/MPI+ is the optoelectronic isolated adapter for industrial design. There is anti-surging&amp;amp; anti-lightning protection circuit for the USB and RS485 interface. It support hot plug. It&amp;rsquo;s suitable for the communication between Siemens S7-300/400 series PLC or other equipments with MPI interface and computer. In particular, it applies to the strong interfere industrial scene and the safeguard in the circuit guarantees the safely running of the system.&lt;/span&gt;&lt;br /&gt;
&amp;nbsp;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;USB/MPI+&amp;nbsp;programming cable simulate USB port as traditional serial port (usually COM3), which enables existing programming software(STEP 7) to communicate through simulated traditional port and PLC devices.&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;Outline configuration:&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&lt;img alt=&quot;&quot; src=&quot;/upload/images/Kollewin/USB-MPIplusv2-0-bild2.gif&quot; style=&quot;width: 611px; height: 175px;&quot; /&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;

&lt;p&gt;&amp;nbsp;&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;signals definition of the RS485-Block (DB9M) of the USB/MPI +&lt;/strong&gt;&lt;/p&gt;

&lt;table border=&quot;1&quot; cellpadding=&quot;1&quot; cellspacing=&quot;1&quot; style=&quot;width: 500px;&quot;&gt;
	&lt;tbody&gt;
		&lt;tr&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;pin&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;signal&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;Description&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;1&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;NC&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;No use&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;2&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;M24V&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;24VDC power negative&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;3&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;B&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;RS485 signals positive&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;4&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;RTSAS&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;Data reception control&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;5&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;GND&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;RS485 Signal Ground&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;6&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;NC&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;No use&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;7&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;P24V&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;24VDC power positive&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;8&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;A&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;RS485 signals negative&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;9&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;RTS_PG&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;Data sent control&lt;/td&gt;
		&lt;/tr&gt;
	&lt;/tbody&gt;
&lt;/table&gt;

&lt;p&gt;&amp;nbsp;&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;The status of the indicator&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;

&lt;p&gt;&amp;nbsp;&lt;/p&gt;

&lt;table border=&quot;1&quot; cellpadding=&quot;1&quot; cellspacing=&quot;1&quot; style=&quot;width: 500px;&quot;&gt;
	&lt;tbody&gt;
		&lt;tr&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;Indicator&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;Normally on&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;twinkle&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;OFF&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;Power&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;Power normal&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;Fault&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;Fault or Not connected to power&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;Active&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;Online status&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;Transmission of data&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;Not online&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;Tx&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;Fault&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;Send data&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;No data transmission&lt;/td&gt;
		&lt;/tr&gt;
	&lt;/tbody&gt;
&lt;/table&gt;

&lt;p&gt;&amp;nbsp;&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Features and technological index:&lt;/strong&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679;&amp;nbsp;Support Windows2000/Windows XP&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679;&amp;nbsp;Support STEP7 V5.2 and higher&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679;&amp;nbsp;Fully compatible with USB V1.1 and USB V2.0&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679;&amp;nbsp;Power supply by both USB main line and MPI programming port(Total 1W).with Overcurrent Protection and Surge Protection&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679;&amp;nbsp;High optoelectronic isolation voltage up to 1000VDC&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679;&amp;nbsp;The USB port design with surge protection .The RS485 port design with overcurrent protection and lightning protection(500W)&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679;&amp;nbsp;Baud rate of Com port on PC: 19.2Kbps~115.2Kbps&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679;&amp;nbsp;Baud rate of MPI port on PLC: 19.2Kbps~187.5Kbps&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679;&amp;nbsp;Support long distance communication up to&amp;nbsp;1000m&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679;&amp;nbsp;Working temperature -20~+75&amp;#39;C&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679;&amp;nbsp;Length 3 meters.Color:black&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679;&amp;nbsp;One pc supports one USB programming cable only&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;nbsp;Usage:&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;USB device drivers should be installed before using USB/MPI+ programming cable.&amp;nbsp; After completing Driver installation, the corresponding COM port for the USB/MPI+ &amp;nbsp;programming cable will be displayed in the &amp;ldquo;Device Manager&amp;rdquo; of Window. The step next is just to choose this COM port in the programming software and other application software and keep other communication parameters as in the Default settings. And the following steps are exactly the same as in the traditional programming cables with RS232 interfaces. Here are requested to indicate that &amp;quot;USB&amp;quot; option in the local communications interface setting which the software is not support to the programming cable.&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;If the COM port in the programming software with &amp;quot;*&amp;quot; symbols, such as &amp;quot;* COM3&amp;quot;, it&amp;rsquo;s shown that the COM port have faults. Quit the software and plug a USB plug or re-install the USB driver.&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;Please note that Siemens COM port in programming software is up to support the option to COM8.But the ports more than COM8 are able to choose but in fact can not be used!&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;STEP7 software settings:&amp;nbsp;&lt;br /&gt;
&amp;nbsp;&amp;nbsp;&amp;nbsp; Enter the main interface of STEP7 programming software (SIMATIC Manager), click on the &amp;quot;Set PG / PC Interface&amp;hellip;&amp;quot; option under &amp;quot;Options&amp;quot; menu into the PG / PC interface settings.&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;1, Double-click on &amp;quot;PC Adapter (MPI)&amp;quot; to set the parameters of COM port and MPI port. The adapter does not support &amp;quot;PC Adapter (PROFIBUS)&amp;quot; option.&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;2, Click on &amp;quot;Local Connection&amp;quot; option to set the parameters of COM port, correct choose the COM port in the equipment manager after the driver of USB / MPI + USB has been installed, select the 19200 bps or 38400 bps as the baud rate of COM Communication. USB / MPI + will automatically adapt to the choice of baud rate.&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;3, Click &amp;quot;MPI&amp;quot; to set the parameters of MPI interface adapter options, baud rate can be set to 187.5 Kbps, or 19.2 Kbps, USB / MPI + adapter will automatically adapt to the MPI port of the PLC baud rate. Other parameters set as default.&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;4, On-line test can access the points: USB / MPI + connect the MPI port of the S7-300/400PLC with the computer&amp;#39;s USB port. Click on the main menu interface, as shown in a red circle button. If the data in red box is shown as the picture, the on-line test has pasted. As so far, the setting has completely finished. It can do all Operation such as upload, download ,monitoring of the procedures and other operations.&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&amp;nbsp;&lt;/p&gt;

&lt;p&gt;&lt;img alt=&quot;&quot; src=&quot;/upload/images/Kollewin/USB-MPIplusv2-0-bild3.jpg&quot; style=&quot;width: 593px; height: 452px;&quot; /&gt;&lt;/p&gt;

&lt;p&gt;&amp;nbsp;&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Long-distance communications:&lt;/strong&gt;&lt;/p&gt;

&lt;p&gt;For USB/MPI+, the largest communication distance is up to 1000m at the communication speed of 187.5Kbps. It needs to splice 120ohm terminal resistance between 3 and 8 pin on the RS485 port(DB9 Male) to eliminate signal reflection, and connect 24VDC power between 7 and 2 pin. But requires one PFB-G for each PLC.&lt;/p&gt;

&lt;p&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; Please Note: USB interface cable cannot be extended.&lt;/p&gt;

&lt;p&gt;The quality is guaranteed.It&amp;#39;s tested before shippment.Not made by&amp;nbsp; Siemens,OEM product as the replacement.&lt;/p&gt;</description>
                <guid isPermaLink="true">https://oxid4.swd.de/oxid/Products-oxid/Hardware/Fieldbus-Hardware/KOL-USB-MPI-V2-0.html</guid>
                            </item>
                    <item>
                <title>KOL-USB/MPI+V4.0 140,00 ¤</title>
                <link>https://oxid4.swd.de/oxid/Products-oxid/Hardware/Fieldbus-Hardware/KOL-USB-MPI-V4-0.html</link>
                <pubDate>Thu, 29 Oct 2015 19:24:12 +0100</pubDate>
                <description>&lt;img src=&#039;https://oxid4.swd.de/oxid/out/pictures/generated/product/1/150_150_75/USB-MPIplusv4-0-produktbild.jpg&#039; border=0 align=&#039;left&#039; hspace=5&gt;&lt;h1 class=&quot;productGeneral&quot; id=&quot;productName&quot; style=&quot;margin: 0.3em; font-size: 13px; color: rgb(50, 67, 74); font-family: Tahoma; line-height: 13px;&quot;&gt;&lt;strong style=&quot;color:#B22222;font-size:16px;&quot;&gt;USB/MPI+ V4.0:USB isolated Siemens S7-200/300/400 PLC adapter&lt;/strong&gt;&lt;/h1&gt;

&lt;p&gt;&amp;nbsp;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;PLC MPI or S7-200 PLC PPI communication. It&amp;rsquo;s the same as Siemens PC&lt;br /&gt;
Adapter USB except that this USB/MPI+ V4.0 doesn&amp;rsquo;t support profibus&lt;br /&gt;
communication. Its driver is the Siemens PC_Adapter_USB driver, and choose&lt;br /&gt;
the USB port, not the COM port.&lt;br /&gt;
The working power supply of this cable USB/MPI+ V 4.0 is directly from the USB&lt;br /&gt;
port, but not the PLC programming interface.&lt;br /&gt;
USB/MPI+ V 4.0 is the optoelectronic isolated adapter for industrial design. There&lt;br /&gt;
is anti-surging&amp;amp; anti-lightning protection circuit for the USB and RS485 interface.&lt;br /&gt;
It support hot plug. It&amp;rsquo;s suitable for S7-300/400/200 series PLC. In particular, it&lt;br /&gt;
applies to the strong interfere industrial scene and the safeguard in the circuit&lt;br /&gt;
guarantees the safely running of the system.&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;USB/MPI+ principle and figure structure:&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;

&lt;p&gt;&lt;img alt=&quot;&quot; src=&quot;/upload/images/Kollewin/USB-MPIplusv4-0-bild-1.jpg&quot; style=&quot;width: 636px; height: 206px;&quot; /&gt;&lt;/p&gt;

&lt;p&gt;&lt;img alt=&quot;&quot; src=&quot;/upload/images/Kollewin/USB-MPIplusv4-0-bild-2.jpg&quot; style=&quot;width: 553px; height: 283px;&quot; /&gt;&lt;/p&gt;

&lt;p&gt;&amp;nbsp;&lt;/p&gt;

&lt;p&gt;&amp;nbsp;&lt;/p&gt;

&lt;table border=&quot;1&quot; cellpadding=&quot;1&quot; cellspacing=&quot;1&quot; style=&quot;width: 500px;&quot;&gt;
	&lt;tbody&gt;
		&lt;tr&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;Indicator&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;On&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;Flash&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;Off&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;PWR USB&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;Power On&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;Error&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;Error Or Power off&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;RxD&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;Error&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;Data exchange from PLC&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;Not Connected&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;TxD&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;Error&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;Data exchange to PLC&lt;/td&gt;
			&lt;td style=&quot;text-align: center;&quot;&gt;No Data exchange&lt;/td&gt;
		&lt;/tr&gt;
	&lt;/tbody&gt;
&lt;/table&gt;

&lt;p&gt;&amp;nbsp;&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;Indicator&amp;nbsp;State&amp;nbsp;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;

&lt;p&gt;&amp;nbsp;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;Functions&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679;&amp;nbsp;Support Windows2000/Windows XP/Vista&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679;&amp;nbsp;Support STEP7 V5.2 and higher,STEP7 Micro/Win 4.0 and higher&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679;&amp;nbsp;Fully compatible with USB V2.0&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679;&amp;nbsp;Power supply by USB port(100mA). with overcurrent Protection and Surge Protection&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679;&amp;nbsp;High optoelectronic isolation voltage up to 1000VDC&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679;&amp;nbsp;The USB port design with surge protection.&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679;&amp;nbsp;The RS485 port design with overcurrent protection and lightning&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;protection:Ipp=100A(10/700us,4KV) .Accord to the standard:ITU-TK20/21,VDE0433. &amp;plusmn;15KV ESD Protection.&amp;nbsp;&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679;&amp;nbsp;Baud rate of MPI port on PLC: 19.2Kbps,187.5Kbps,1.5Mbps. automatically adjust.&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679;&amp;nbsp;Baud rate of PPI port on PLC: 9.6Kbps,19.2Kbps,187.5Kbps.&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;automatically adjust.&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679;&amp;nbsp;Support long distance communication up to&amp;nbsp;1000m&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679;&amp;nbsp;Working temperature -20~+75&amp;#39;C&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679;&amp;nbsp;Length 3 meters.Color:black&lt;/span&gt;&lt;/p&gt;

&lt;p&gt;&lt;span style=&quot;color:black;font-size:14px;&quot;&gt;&amp;#9679;&amp;nbsp;One pc supports one USB programming cable only&lt;/span&gt;&lt;/p&gt;</description>
                <guid isPermaLink="true">https://oxid4.swd.de/oxid/Products-oxid/Hardware/Fieldbus-Hardware/KOL-USB-MPI-V4-0.html</guid>
                            </item>
        </channel>
</rss>