OPT-G4OAC5A5FM

Product 83 of 131
Zoom
OPTO22 5VDC Logik Ausgabemodul Gen.4 Schaltmodul 24-280V/AC, 3A, normally closed, Factory Mutual approved
plus VAT Weight: 0.2 kg RegulÀr Regular Neu New
G4OAC5A5FM G4 AC Output 24-280 VAC, 5 VDC Logic, Normally Closed, Factory Mutual Approved
Opto 22 G4OAC5A5FM Opto 22 Logo
Opto 22’s G4 AC output modules are used to control or switch AC loads. Each module provides up to 4000 volts of
optical isolation (transient) between field outputs and the control side of the circuit, and each features zero voltage turn-
on and zero current turn-off. This AC output module is equivalent to a single-pole, single-throw, normally open contact
(Form A, SPST-NO).

Typical applications for AC output modules include switching loads such as AC relays, solenoids, motor starters,
heaters, lamps, and indicators.

This module is Factory Mutual approved. If you do not need FM approval, see the G4OAC5A5.

Units G4OAC5
G4OAC5FM*
G4OAC5A
G4OAC5AFM
G4OAC5A5
G4OAC5A5FM
G4OAC5MA G4OAC5AMA
Nominal line voltage VAC 120 120/240 120/240 120 120/240
Output voltage range VAC 12-140 24-280 24-280 12-140 24-280
Key feature Normally closed Diagnostic
switch
Diagnostic
Switch
Current rating:
At 45 °C ambient
At 70 °C ambient

A
A

3
2

3
2

3
2

3
2

3
2
UL Motor Load Rating A 1.5 1.5 1.5 1.5 1.5
Isolation input-to-output
(transient):
1 ms
1 minute
volts

4000
1500


4000
1500


4000
1500


4000
1500


4000
1500
Off-state leakage at
nominal voltage (60 Hz)
mARMS 5 1.25/2.5 1.25/2.5 5 1.25/2.5
Nominal logic voltage VDC 5 5 5 5 5
Logic voltage range VDC 4-8 4-8 4-8 4-8 4-8
Logic pickup voltage VDC 4 4 4 4 4
Logic dropout voltage VDC 1 1 1 1 1
Logic input current at
nominal logic voltage
mA 12 12 12 12 12
Control resistance
(Rc in schematic)
ohms 220 220 220 220 220
One-cycle surge A peak 80 80 80 80 80
Turn-on time @ 60 Hz milliseconds ≤8.3** ≤8.3** ≤8.3** ≤8.3** ≤8.3**
Turn-off time @ 60 Hz milliseconds ≤8.3*** ≤8.3*** ≤8.3*** ≤8.3*** ≤8.3***
Peak repetitive voltage VAC 500 500 500 500 500
Minimum load current mA 20 20 20 20 20
Output voltage drop
maximum peak
V 1.6 1.6 1.6 1.6 1.6
Operating frequency Hz 25-65 25-65 25-65 25-65 25-65
dV/dT-off-state V/micro-
second
200 200 200 200 200
dV/dT-commutating -- snubbed for 0.5
power factor load
snubbed for 0.5
power factor load
snubbed for 0.5
power factor load
snubbed for 0.5
power factor load
snubbed for 0.5
power factor load
Temperature
Operating:
Storage:

°C
°C

-30 to +70
-30 to +85

-30 to +70
-30 to +85

-30 to +70
-30 to +85

-30 to +70
-30 to +85

-30 to +70
-30 to +85
* Part numbers ending in FM are Factory Mutual approved.
** One-half cycle maximum. Module turns on at the zero volt crossing of the AC sine wave.
*** One-half cycle maximum. Module turns off at the zero current crossing of the AC sine wave.

Rev: 04/13