© 2013 Uwe Wannags Hard-+ Software Distribution e.K (SWD)
OPT-DC200P
| DC200P P Model, 200 VDC, 1 Amp, DC Control Solid State Relay (SSR) |
|
|
DC60P
or DC60MP |
DC200P
or DC200MP |
DC60S-3 | DC60S-5 | |
| Operating Voltage Range | 5–60 VDC | 5–200 VDC | 5–60 VDC | 5–60 VDC |
| Forward Voltage Drop | 1.5 volts
at 3 amps |
1.5 volts
at 1 amp |
1.5 volts
at 3 amps |
1.5 volts
at 5 amps |
| Nominal Currrent Rating | 3 amps | 1 amp | 3 amps | 5 amps |
| Off-State Blocking | 60 VDC | 250 VDC | 60 VDC | 60 VDC |
| Signal Pick-up Voltage | 3VDC
32 Volts* allowed |
3VDC
32 Volts* allowed |
3VDC
32 Volts* allowed |
3VDC
32 Volts* allowed |
| Signal Dropout Voltage | 1 VDC | 1 VDC | 1 VDC | 1 VDC |
| Signal Input Impedeance | 1,000 ohms | 1,000 ohms | 1,000 ohms | 1,000 ohms |
| 1 Second Surge | 5 amps | 2 amps | 5 amps | 10 amps |
| Operating Temp. Range | –40 °C to
100 °C |
–40 °C to
100 °C |
–40 °C to
100 °C |
–40 °C to
100 °C |
| Isolation Voltage | 4,000VRMS | 4,000VRMS | 4,000VRMS | 4,000VRMS |
| Off-State Leakage | 1 mA
maximum |
1 mA
maximum |
1 mA
maximum |
1 mA
maximum |
| Package Type | P/MP series | P/MP series | Power series | Power series |
| Turn-on time | 100 usec | 100 usec | 100 usec | 100 usec |
| Turn-off time | 750 usec | 750 usec | 750 usec | 750 usec |
| Note: *MP series maximum allowed control signal at 24 VDC. | ||||
Rev: 04/13