OPTO 22 Typ J Thermocouple Input Module Isolated
plus VAT Weight: 0.2 kg RegulÀr Regular Neu New
AD5T J Thermocouple Input Isolated
Opto 22 AD5T Opto 22 Logo

 

AD5

AD5T

AD8

AD8T

Thermocouple Type

J

J

K

K

Nominal Temperature
Range °C

0° to 700°

0° to 700°

-100° to 924°

-100° to 924°

Nominal Temperature
Range °F

32° to 1292°

32° to 1292°

-148° to 1695°

-148° to 1695°

Over/Under Range
Capability °C

-20° to 1200°

-20° to 1200°

-125° to 1250°

-125° to 1250°

Over/Under Range
Capability °F

- 4° to 2192°

- 4° to 2192°

-193° to 2282°

-193° to 2282°

Average
Resolution

0.18 °C
  (0 to 700 °C)
0.36 °C
  (700 to 1200 °C)

0.18 °C
  (0 to 700 °C)
0.36 °C
  (700 to 1200 °C)

± 0.25 °C
  (-100 to 924 °C)
± 0.5 °C
  (924 to 1250 °C)

± 0.25 °C
  (-100 to 924 °C)
± 0.5 °C
  (924 to 1250 °C)

Accuracy*

± 3 °C (0 to 700 °C)

± 3 °C (0 to 700 °C)

± 3 °C (-100 to 924 °C)

± 3 °C (-100 to 924 °C)

Repeatability

± 1 °C

± 1 °C

± 1 °C

± 1 °C

Power
Requirements

17 mA at +15 VDC
12 mA at -15 VDC

35 mA at +15 VDC
35 mA at -15 VDC

17 mA at +15 VDC
12 mA at -15 VDC

35 mA at +15 VDC
35 mA at -15 VDC

*Accuracy may be improved by the use of "Set Offset" and "Set Gain" commands in the OPTOMUX command set.