OPTO 22 SNAP 32-channel Pamux Protocol Digital Brain Board
plus VAT Weight: 0.4 kg RegulÀr Regular Neu New
SNAP-B4 SNAP 32-channel Pamux Protocol Digital Brain Board
Opto 22 SNAP-B4 Opto 22 Logo
Part
Number
Description1 Power2
Requirements
I/O Processor3
Compatibility
Replacement
Fuse
Operating
Temperature
Relative
Humidity
SNAP-
M16
4-module mixed4 5.0 to 5.2 VDC @
4.2 Amps max
SNAP-PAC-R1

SNAP-PAC-R2

SNAP-UP1-M64

SNAP-ENET-S64

SNAP-
FUSE7.5AB
or Littelfuse6
297 07.5

0 to 70 °C

95%, non-condensing

SNAP-
M32
8-module mixed4
SNAP-
M48
12-module mixed4
SNAP-
M64
16-module mixed4
SNAP-
B4M
4-module mixed 5.0 to 5.2 VDC @
1.8 Amps max
SNAP-UP1-ADS

SNAP-B3000-ENET

SNAP-ENET-RTC

B3000

B3000-HA

SNAP-B4

SNAP-B6

SNAP-BRS

SNAP-BRS-HA

SNAP-B3000-MODBUS

SNAP-FUSE4A

or Bel6 5HF4

SNAP-
B8M
8-module mixed 5.0 to 5.2 VDC @
2.6 Amps max
SNAP-
B8MC
8-module mixed,
terminal block
SNAP-
B8MC-P
8-module mixed,
pluggable terminal
block
SNAP-
B12M
12-module mixed5 5.0 to 5.2 VDC @
3.4 Amps max
SNAP-
B12MC
12-module mixed5,
terminal block
SNAP-
B12MC-P
12-module mixed5,
pluggable terminal
block
SNAP-
B16M
16-module mixed5 5.0 to 5.2 VDC @
4.2 Amps max
SNAP-
B16MC
16-module mixed5,
terminal block
SNAP-
B16MC-P
16-module mixed5,
pluggable terminal
block
SNAP-
D64RS
16-module digital
only (limited digital
functions)
5.0 to 5.2 VDC @
1.8 Amps max
SNAP-UP1-D64
SNAP-ENET-D64
SNAP-PDPRS64
SNAP-FUSE1A
or Buss6
GDC1A
1 “Mixed” means the rack can hold analog, digital, and serial modules. Most Ethernet-based I/O processors handle all
these types of modules; other processors do not. See the processor’s data sheet for details.
 
2 Power requirements shown are for a rack, a processor, and a full load of 2-channel analog modules (for the SNAP-
D64RS, a full load of 4-channel digital modules). Power requirements for other SNAP modules are higher. See module data
sheets.
 
3 “I/O Processor” means a SNAP brain or on-the-rack controller.
 
4 Digital features and module positions depend on processor. SNAP-PAC-R1 supports full digital features (high-speed
counting, quadrature counting, TPO, pulsing), but on larger racks, 4-channel SNAP digital modules must be in positions
0–7 only (32-channel digital modules can be in any position). SNAP-PAC-R2, SNAP-UP1-M64, and SNAP-ENET-S64 offer
more limited digital features but can use digital modules in any position. See the processor’s data sheet for details.
 
5 Four-channel SNAP digital modules can be used in positions 0–7 only.
 