COR-CT-N805A

Artikel 8 VON 8
Zoom
B&E (former CorNet) ARCNET Diagnostic Hub 8-ports Coax(CE)
zzgl. MwSt. Gewicht: 2.7 kg Empfohlen Empfohlen Neu Neu

Corman Tech/B&E, CT-N805A

   
 Hersteller / producer:  Corman Tech 
 Produkt-Bez. / brand name:  CT-N805
 Rev.:  
 Ports:  8
 Topology:  ( - )Bus, ( X )Star , ( X )Linking port available
 Abmessungen/Dimensions:  Breite/Width: 220 [mm] x Tiefe/Deep: 190 [mm] x Höhe/Height: 65 [mm] , Gewicht/Weight: 2,00 [kg]
 Connections:  ( X )BNC(600 mtr), ( - )TP/RJ-11(120 mtr),
 Volt(age):  ( - )220/240, ( - )110/130, ( X )220/240<>110/130 [V]
 Netzteil/Power Supply:  ( X ) intern/internal, ( - ) extern/external

CorNet ARCNET Diagnostic Hub 8 Port Coax CE

DESCRIPTION
This is an ARCNET hub with diagnostic LEDs and linking ports. The CT-N800 series of hubs was created to fill a need for an ARCNET hub with additional diagnostic capabilities for tracking down reconfiguration problems without resorting to the complexity and cost of an "Intelligent Hub". These hubs are built to withstand a wide range of temperature and power line voltage swings. The hubs maintain full output levels even when running at maximum temperature and data traffic loads. This stability is provided through the use of a switching regulator in the power supply and attention to detail in the output driver section. The switching regulator produces less heat and withstands brownouts better than a linear regulator. Proper thermal design ensures that heat produced in the output drivers is dissipated via convection air currents in any acceptable mounting position.
   
OPERATING ENVIRONMENT
Power: 120 VAC +6%/- 10% @ l60 mA
240 VAC +6%/- 10% @ 80 mA
50 Hz or 60 Hz
Operating Temperature: 0 to 55 ºC
Storage Temperature: -40 to 125 ºC
Humidity: 5% to 80% (non-condensing)
   
ARCNET LAN INTERFACE
Transmit level 15.4 Vp-p
Receive Sensitivity 3.0 Vp-p
Impedance 93 ohm coax
Connectors BNC connectors
   
PHYSICAL SPECIFICATIONS
Height 2.75 inches
Width 8.5 inches
Depth (including connectors) 7.5 inches
Weight 5 pounds
Included with the hub are two mounting brackets and four bolts for attaching the brackets to the hub. A link cable and one terminator are included for expanding the hub configuration to add more ports or to connect hubs with different types of media. A detachable power cord is also included.
   
INSTALLATION CONSIDERATIONS
Coax Cable type RG62A/U 93 ohm with BNC connectors
Coax Distances From node to hub 2000 ft.
Total network span up to 22,000 ft. (using standard time-outs)
Maximum of 10 active hubs may be between any two nodes on the network
   
Mounting 19" EIA rack mountable
wall mountable
stackable (up to 4 hubs)

CONFORMS TO THE FOLLOWING STANDARDS
ARCNET: ANSI 878.1
EMC: EN55022:1994 (Emissions)
CISPR 22 1993-12 Class A
FCC Part 15 Class A
EN 50082-1 (Immunity)
IEC 801-2:1991
8KV Contact, 8KV Air
IEC 801-3:1984
3V/m
IEC 801-4:1988
0.5 KV Signal line,
1 KV Power line
Safety: EN 60950:1992/A1:1993
IEC 950:1991+A1:1992+A2:1993
UL 1950, cUL (CSA 950 accepted equivalent)

 

Products are marked as certified to the CE standards.

 

Rev: 03/21

Ports 8-port
* zzgl. Versandkosten