OPTO 22 SNAP 32-channel Digital Output Module 5-60VDC Load Sorcing, Factory Mutual Approved
zzgl. MwSt. Gewicht: 0.3 kg RegulÀr Regulär Neu Neu
SNAP-ODC-32-SNK SNAP 32-channel Digital Output Module, 5-60 VDC Load Sinking
Opto 22 SNAP-ODC-32-SNK Opto 22 Logo
The SNAP-ODC-32-SNK digital output module (load sinking) provides 32 digital output channels in one compact SNAP
module. This module is ideal for OEMs and others with applications with high point counts, or for those requiring a large
number of digital output channels on one SNAP I/O rack. The high-density configuration reduces per-point costs of
digital I/O systems by providing up to eight times as many I/O channels in the same space.
 
Part of the SNAP PAC System, the module mounts on a SNAP PAC rack with a SNAP PAC brain or rack-mounted
controller. Analog, digital, and serial I/O modules can all be on the same rack. Such an I/O unit is also well suited for
PC-based control or for use as intelligent remote I/O for an Allen-Bradley MicroLogix or other RSLogix-based PLC
system, such as ControlLogix or CompactLogix.
 
For easy field wiring, use the SNAP-ODC-HDB breakout rack and the SNAP-HD-BF6 header cable. A wiring harness with
flying leads (SNAP-HD-CBF6) is also available.
 
NOTE: If you need a Factory Mutual-approved version, see the SNAP-ODC-32-SNK-FM.
 
  SNAP-ODC-32-SRC
SNAP-ODC-32-SRC-FM
SNAP-ODC-32-SNK
SNAP-ODC-32-SNK-FM
Switching Voltage 5–60 VDC 5–60 VDC
Nominal Switching
Voltage
12–24 VDC 12–24 VDC
Logic Voltage and Current 5 VDC ± 0.1 @ 150 mA 5 VDC ± 0.1 @ 150 mA
Maximum Off State
Voltage
60 VDC 60 VDC
Output Leakage, Typical <10 microamps per channel (60 V, 70 °C) <10 microamps per channel (60 V, 70 °C)
Maximum Load per Point 0.25 A 0.25 A
Voltage Drop 0.15 VDC @ 0.25 A 0.15 VDC @ 0.25 A
Surge (1 sec.) 1 A 1 A
Output Arrangement 32 output channels; 4 groups of 8 outputs
each. Points in each group share a common
positive connection.
32 output channels; 4 groups of 8 outputs
each. Points in each group share a common
negative connection.
Output Turn-On/Off Time 100 microseconds 100 microseconds
Polling time from I/O
processor to module1
2–30 ms typical2 2–30 ms typical2
Indicators None; use optional OptoTerminal-G20
diagnostic display or breakout rack.
None; use optional OptoTerminal-G20
diagnostic display or breakout rack.
Maximum Number of HDD
Modules on One Mounting
Rack
16 16
Agency Approvals SNAP-ODC-32-SRC: UL, CE, RoHS, DFARS
 
SNAP-ODC-32-SRC-FM: CE, FM, RoHS, DFARS
SNAP-ODC-32-SNK: UL, CE, RoHS, DFARS
 
SNAP-ODC-32-SNK-FM: CE, FM, RoHS, DFARS
Torque, hold-down screws 4 in-lb (0.45 N-m) 4 in-lb (0.45 N-m)
Torque, connector screws 5.26 in-lb (0.6 N-m) 5.26 in-lb (0.6 N-m)
Warranty Lifetime Lifetime
1 Affects turn-on and turn-off determination
2 Time varies based on the SNAP PAC I/O processor (brain or on-the-rack controller), processor configuration, and
Ethernet host communication activity.

Rev: 04/13