COM-32062-3

Product 8 of 11
Zoom
32062-3 RocketLinx ES8510-XTE Managed 10-Port industrial Ethernet switch with extended temperature, NEMA TS2
Select
  • Block price:

  • pcs
  • 2.5 % Discount
  • 5 % Discount
  • 10 % Discount
  • 12.5 % Discount
  • 15 % Discount
  • 17.5 % Discount
  • 20 % Discount
plus VAT Weight: 1.8 kg RegulÀr Regular Neu New

32062-3 RocketLinx ES8510-XTE Managed 10-Port industrial Ethernet switch with extended temperature, NEMA TS2

Managed Industrial Ethernet switch, seven Fast Ethernet ports, and three Fast Ethernet Ethernet combo ports, extended operating temperature range

Part Number: 32062-3

  • Seven 10/100BASE-TX ports and three RJ45/SFP combo (10/100BASE-TX, 100BASE-FX)
  • Enhanced redundancy featuring multiple redundant ring technology (recovery time <5ms)
  • Non-blocking switching, 8K MAC address table, 32 Gbps switch fabric
  • VLAN, GVRP, QoS, IGMP snooping V1/V2/V3, rate control, port trunking, LACP, online multi-port mirroring
  • Management via console CLI, Web, SNMP V1/V2c/V3, RMON, HTTPS, SSH and NetVision
  • Advanced security feature supports IP security, port security, DHCP server, IP and MAC binding, IEEE 802.1x network access control
  • Event notification by email, SNMP trap, syslog, digital input and relay output
  • Rigid aluminum IP31 housing, excellent heat dispersion, redundant power, DIN rail/wall-mount installation
  • Extended operating temperature range (-40°C to +74°C)
  • NEMA TS2 certified
  • IPV6 support

 

 

System Specifications - RocketLinx ES8510-XTE Fast Ethernet Switches
Hardware

 

 

  • Network Interfaces10/100BASE-TX
    100BASE-FX
  • Connector TypesRJ45 
    SFP
  • EnclosureIP31 Grade Aluminum Metal Case
  • InstallationDIN Rail, wall mount
  • LED IndicatorsPower 1, Power 2, ring master (R.M.)
    10/100BASE-TX link/activity
    10/100BASE-TX full duplex/collision
    Copper/SFP combo activity
    Digital input 1&2, digital output 1&2
  • Digital Input (DI)Two digital inputs
    4-Pin screw terminal block
  • Digital Output (DO)Two digital outputs (dry relay output)
    4-Pin screw terminal block
  • Serial Console PortOne RJ45 RS-232 (TXD, RXD, Signal GND), Baud Rate: 9600bps,
    Data Bits: 8, Parity: None, Stop Bits: 1, Flow Control: None
  • Dimensions5.0" x 6.3" x 3.7" 
    127 x 160 x 94 mm
  • Product Weight2.63 lbs 
    1.19 kg
Ethernet Specifications
  • Number of PortsTen: 7 Standard Fast Ethernet and 3 combo RJ45/SFP Fast Ethernet
  • RJ45 (Standard)10/100BASE-TX, Auto MDI/MDIX, Auto-Negotiation (Speed/Duplex Mode)
  • SFP (Optional)100BASE-FX Fiber, Auto MDI/MDIX, Auto-Negotiation (Speed/Duplex Mode)
  • Cable TypesCAT-3, CAT-4, CAT-5, CAT-5e (UTP or STP)
  • Link DistancesRJ45: 100 Meters
    SFP: Depends on Model: Single-Mode: 30KM, Multi-Mode: 2KM
  • Port Alarm RelayYes
  • StandardsIEEE 802.1AB: Link Layer Discovery Protocol (LLDP) 
    IEEE 802.1D-2004: Rapid Spanning Tree Protocol (RSTP) 
    IEEE 802.1p: Class of Service
    IEEE 802.1Q VLAN Tagging and GVRP
    IEEE 802.1s: Multiple Spanning Tree Protocol (MSTP) 
    IEEE 802.1X: Port Based Network Access Control
    IEEE 802.3:10BASE-T
    IEEE 802.3ad: Link Aggregation Control Protocol (LACP) 
    IEEE 802.3u: 100BASE-TX, 100BASE-FX
    IEEE 802.3x: Flow Control and Back-Pressure

Management Features

  • Configuration ManagementOut-band management: console port with command line interface (CLI) - similar to Cisco CLI, in-band management: NetVision (Windows application), web interface (HTTP/HTTPS) or a Telnet/SSH console with CLI
  • Embedded WatchdogEmbedded hardware watchdog timer automatically resets system if switch system failure occurs
  • System Upgrade/BackupTFTP/Web Interface for Firmware Upgrade and Configuration Backup/Restore
  • SNMPV1, V2c, V3 with SNMP trap function, up to four trap stations
  • SNMP MIBMIB-II, bridge MIB, VLAN MIB, IGMP MIB, Ethernet-like MIB, Comtrol private MIB, and RMON
  • Email WarningAutomatic warning, up to four accounts by pre-defined events
  • System LogSupports both local mode and server mode supported
  • DHCPDHCP client, DHCP server with IP and MAC address binding and DHCP

Network Performance

  • Back-PressureIEEE 802.3x: 10/100Mbps half-duplex only
  • Class of Service (CoS)IEEE 802.1p: 4 priority level (0-7), queue ID (0-3)
  • Flow Control Pause FrameIEEE 802.3x: 10/100Mbps Full-Duplex
  • IGMP SnoopingV1/V2 /V3 for multicast filtering and IGMP query V1/V2; supports unknown multicasting, processes forwarding policies: drop, flooding and forward to router port, 256 IGMP multicast groups
  • IP SecurityAssign Authorized IP Addresses to Specific Port, 10 Max/Port
  • Time SynchronizationSupports NTP protocol with daylight saving function, and localized time sync function
  • Port-Based Network Access ControlIEEE 802.1X: supports user authentication by the RADIUS account, password and key for the RADIUS servers (primary and secondary)
  • Port ConfigurationPort link speed, link mode, port status, enable/disable
  • Port MirroringOnline traffic monitoring on multiple selected ports
  • Port SecurityAssign authorized MAC addresses to specific port, 10 max/port
  • Port Trunk (Max)IEEE 802.3ad LACP with timer and static port trunk; trunk member up to 8 ports and maximum 5 trunk groups
  • Private VLANDirect Client Ports in Isolated/Community VLAN to Promiscuous Port in Primary VLAN
  • Rate ControlIngress filtering for broadcast, multicast, unknown DA or all packets
    Egress filtering for all packets
  • Switch Technology32Gbps switch fabric, store and forward Switch Technology, 8K MAC Address
  • System Throughput2.976Mpps
    64 byte Packet Size
  • Transfer Packet Size64 bytes to 1522 bytes (includes 1522 bytes VLAN tag)
  • Packet Buffer1Mbits shared memory
  • Traffic Prioritization (QoS)Supports 4 physical queues, weighted round robin queuing (WRR 8:4:2:1) and strict priority scheme (IEEE 802.1p COS tag and IPv4 ToS/diffserv information) to prioritize industrial network traffic
  • VLAN (Max)IEEE 802.1Q: Tag VLAN with 256 (Max) VLAN entries, 2K GVRP entries; 3 VLAN link modes (trunk, hybrid, and link access)
  • Modbus TCP/IPCLI support for Modbus TCP/IP communications with function code 4 (factory automation). Operates as slave/server device, while a typical master/client device is a host computer running appropriate through Ethernet, The Modbus TCP/IP master can read or write to the Modbus registers provided by the Modbus TCP/IP. Application software (SCADA / HMI System)

Network Redundancy

  • Rapid Spanning Tree Protocol (RSTP)IEEE 802.1D-2004 RSTP
    Compatible with Legacy STP and IEEE 802.1w
  • Multiple Spanning Tree ProtocolIEEE 802.1s MSTP: each MSTP instance can include one or more VLANS and supports multiple RSTPs deployed in a VLAN or multiple VLANs
  • Redundant Ring TechnologyFailure Recovery within 5ms 
    Rapid Dual Homing: Multiple Uplink Paths to Upper Switches
    Ring Trunking: Integrates Port Aggregate Function in Ring Path to Get Higher
    Throughput Ring Architecture
    Multiple Ring: Couple or Multiples of Up to 16 Rings, Supports Up to 5 Fast Ethernet Rings/Switch
Electrical Specifications
  • Device
    • DC Input Voltage
      (Positive or Negative)
      10 to 60VDC
    • Current Consumption+24VDC @ 1A
    • Power Consumption (max.)24W
  • Number of Power Connector1
  • Power Connector Type4-Pin screw terminal block
  • Power Input RedundancyDual redundant inputs
  • Reverse Polarity ProtectionYes
  • Digital Input2 with photo optical isolation
    • Logic Low (0)0 to 10VDC
    • Logic High (1)11 to 30VDC
  • Digital Output (Relay Output)2
    • DC Input Voltage24VDC
    • Current Consumption (24VDC)1A maximum
Environmental Specifications
  • Air Temperature
    • System On-40° to 74° C
    • System Off-40° to 85° C
  • Operating Humidity (non-condensing)5% to 95%
  • MTBF (Mean Time Between Failures)34.6 years
Export Information
  • Packaged Shipping Weight3.9 lbs 
    1.77 kg
  • Package Dimensions11.3" x 5.5" x 9.1" 
    28.7 cm x 13.97 cm x 23.11 cm
  • UPC Code7-56727-32062-3
  • ECCN5A992
  • Schedule B Number8517.62.0050
Regulatory Approvals
  • EmissionsCanadian EMC Requirements
    ICES-003
    European Standard EN55022
    EN61000-6-4
    CISPR 22
    FCC Part 15 Subpart B
    Class A limit
  • ImmunityEuropean Standard EN55024:
    IEC 61000-6-2
    IEC 1000-4-2/EN61000-4-2: ESD 
    IEC 1000-4-3/EN61000-4-3: RF
    IEC 1000-4-4/EN61000-4-4: Fast Transient/Burst
    IEC 1000-4-5/EN61000-4-5: Surge 
    IEC 1000-4-6/EN61000-4-6: Conducted Distrubance
    IEC 1000-4-8/EN61000-4-8: Magnetic Field 
    IEC 1000-4-11/EN61000-4-11: DIPS and voltage Variations
  • SafetyIEC 60950/EN60950 (LISTED)
    CSA C22.2 No. 60950/UL60950 Third edition
  • ShockIEC 60068-2-27
  • VibrationIEC 60068-2-6
  • Free FallIEC 60068-2-32
  • Hi-PortAC 1.2KV for All Ports and Power
  • Regulatory ApprovalsEuropean Standard: 2002/95/EC Directive (RoHS)
    NEMA TS2 Certified

Rev: 07/18

* plus shipping